English
Language : 

SSTW003A0A Datasheet, PDF (8/15 Pages) Lineage Power Corporation – 36-75Vdc Input; 5.0Vdc, 3A, 15W Output
GE
Data Sheet
SSTW003A0A Barracuda™ Series; DC-DC Converter Power Modules
36-75Vdc Input; 5.0Vdc, 3A, 15W Output
Feature Descriptions (continued)
Vin+
Vout+
ON/OFF
TRIM
Vin-
Vout-
Radj-up
RLOAD
Figure 12. Circuit Configuration to Increase Output Voltage.
The SSTW power modules have a fixed current-limit set point.
Therefore, as the output voltage is adjusted down, the
available output power is reduced.
Trim Examples
For SSTW003A0A, nominal 5.0V module. To trim module down
to 4.90V:
Radj

down




(4.9  2.5)  5110
(5.0  4.9)

2050

Radj  down  120,590
Thermal Considerations
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be provided
to help ensure reliable operation.
Considerations include ambient temperature, airflow, module
power dissipation, and the need for increased reliability. A
reduction in the operating temperature of the module will
result in an increase in reliability.
The thermal data presented here is based on physical
measurements taken in a wind tunnel, using automated
thermo-couple instrumentation to monitor key component
temperatures: FETs, diodes, control ICs, magnetic cores,
ceramic capacitors, opto-isolators, and module pwb
conductors, while controlling the ambient airflow rate and
temperature. For a given airflow and ambient temperature, the
module output power is increased, until one (or more) of the
components reaches its maximum derated operating
temperature, as defined in IPC-9592A. This procedure is then
repeated for a different airflow or ambient temperature until a
family of module output derating curves is obtained.
Figure 13. Thermal Test Setup .
LOCAL AMBIENT TEMPERATURE, TA (C)
Figure 14. Output Current Derating for the Open Frame
SSTW003A0A in the Transverse Orientation; Airflow
Direction from Vin(-) to Vin(+); Vin = 48V.
The thermal reference point, Tref used in the specifications is
shown in Figure 15. For reliable operation this temperature
should not exceed 111oC.
March 26, 2013
Figure 15. Tref Temperature Measurement Location.
Heat Transfer via Convection
Increased airflow over the module enhances the heat transfer
via convection. Derating figures showing the maximum output
©2012 General Electric Company. All rights reserved.
Page 8