English
Language : 

LW015A91 Datasheet, PDF (8/24 Pages) Lineage Power Corporation – LC/LW010- and LC/LW015-Series Power Modules 18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 10 W and 15 W
LC/LW010- and LC/LW015-Series Power Modules:
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 10 W and 15 W
Data Sheet
March 27, 2008
Characteristics Curves (continued)
5.15
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0.00
0 10 20 30 40 50 60 70 80
INPUT VOLTAGE, V I (V)
8-1787(C)
Figure 3. LW010 Input Current vs. Input Voltage at
IO = IO, max and TC = 25 °C
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
0
10 20
30 40
50 60
70 80
INPUT VOLTAGE, V I (V)
8-1788(C)
Figure 4. LW015 Input Current vs. Input Voltage at
IO = IO, max and TC = 25 °C
1.003
1.002
1.001
1.000
VI = LOW LINE
0.999
0.998
VI = NOM LINE
VI = HIGH LINE
0.997
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
NORMALIZED OUTPUT CURRENT (IO/IO, max)
8-1789(C)
Figure 5. Lx010x/Lx015x Single-Output Load
Regulation, Normalized Output Voltage
vs. Normalized Output Current at
TC = 25 °C
5.10
5.05
VI = LOW LINE
VI = NOM LINE
VI = HIGH LINE
5.00
4.95
4.90
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
OUTPUT CURRENT 1, IO1 (A)
Note: Output2 has characteristics similar to output1 when
IO1 = 0.5 A and IO2 varies.
8-1790(C)
Figure 6. Lx010AJ Typical Load Regulation of
Output1 with Fixed IO2 = 0.5 A at
TC = 25 °C
5.25
5.20
VI = LOW LINE
5.15
5.10
VI = NOM LINE
VI = HIGH LINE
5.05
5.00
4.95
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
OUTPUT CURRENT 2, IO2 (A)
Note: Output2 has characteristics similar to output1 when
IO2 = 0.1 A and IO1 varies.
8-1791(C)
Figure 7. Lx010AJ Typical Cross Regulation,
VO1 vs. IO2 with Fixed IO1 = 0.1 A at
TC = 25 °C
8
Lineage Power