English
Language : 

JC050A1 Datasheet, PDF (4/16 Pages) Lineage Power Corporation – Small size: 61.0 mm x 57.9 mm x 12.7 mm (2.40 in. x 2.28 in. x 0.50 in.)
JC050A, JC075A, JC100A Power Modules: dc-dc Converters;
18 Vdc to 36 Vdc Input, 5 Vdc Output; 50 W to 100 W
Data Sheet
March 2008
General Specifications
Parameter
Calculated MTBF (IO = 80% of IO, max; TC = 40 °C)
Weight
Min
Typ
Max
Unit
2,600,000
hr.
—
—
100 (3.5) g (oz.)
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
Parameter
Remote On/Off Signal Interface
(VI = 0 V to 36 V; open collector or equivalent compatible;
signal referenced to VI(–) terminal; see Figure 17 and
Feature Descriptions.):
JCxxxA1 Preferred Logic:
Logic Low—Module On
Logic High—Module Off
JCxxxA Optional Logic
Logic Low—Module Off
Logic High—Module On
Logic Low:
At Ion/off = 1.0 mA
At Von/off = 0.0 V
Logic High:
At Ion/off = 0.0 µA
Leakage Current
Turn-on Time (See Figure 13)
(IO = 80% of IO, max; VO within ±1% of steady state)
Output Voltage Adjustment (See Feature Descriptions.):
Output Voltage Remote-sense Range
Output Voltage Set-point Adjustment Range (trim)
Output Overvoltage Clamp
Overtemperature Shutdown
(100 W only; see Feature Descriptions.)
Symbol Min Typ Max
Unit
Von/off
0
— 1.2
V
Ion/off
—
— 1.0
mA
Von/off
—
—
15
V
Ion/off
—
—
50
µA
—
— 20 35
ms
—
— — 0.5
—
60 — 110
VO, clamp 5.9
—
7.0
Tc
— 105 —
V
%VO, nom
V
°C
4
Lineage Power