Electrical Specifications (continued)
Parameter
Dynamic Load Response
(dIo/dt=0.1A/μs; VIN = VIN, nom; TA=25°C)
Load Change from Io= 50% to 75% or 25% to
50% of Io,max;
Peak Deviation
Settling Time (Vo<10% peak deviation)
(dIo/dt=1A/μs; VIN = VIN, nom; TA=25°C)
Load Change from Io= 50% to 75% or 25% to
50% of Io,max;
Peak Deviation
Settling Time (Vo<10% peak deviation)
Device
All
All
All
All
Symbol
Min
Typ
Vpk
⎯
3
ts
⎯
200
Vpk
⎯
5
ts
⎯
200
Max
Unit
⎯
% VO, set
⎯
μs
⎯
% VO, set
⎯
μs
Isolation Specifications
Parameter
Isolation Capacitance
Isolation Resistance
I/O Isolation Voltage (100% factory Hi-pot tested)
Device Symbol Min
All
Ciso
⎯
All
Riso
10
All
All
⎯
Typ
1000
⎯
⎯
Max
⎯
⎯
1500
Unit
pF
MΩ
Vdc
General Specifications
Parameter
Calculated Reliability based upon Telcordia SR-
332 Issue 2: Method I Case 3 (IO=80%IO, max,
TA=40°C, airflow = 200 lfm, 90% confidence)
Weight
Device
Symbol
Min
Typ
Max
Unit
B
FIT
A-S
FIT
F
FIT
Y
FIT
334
109/Hours
290
109/Hours
328
109/Hours
302
109/Hours
B
MTBF
2,997,896
Hours
A-S
MTBF
3,451,558
Hours
F
MTBF
3,051,626
Hours
Y
MTBF
3,312,888
Hours
All
⎯
11.3
(0.4)
⎯
g
(oz.)
LINEAGE POWER