QBDW025A0B Datasheet, PDF (19/32 Pages) Lineage Power Corporation – 36-75Vdc Input; 12.0Vdc, 25.0A, 300W Output
GE
Data Sheet
QBDW025A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 25.0A, 300W Output
The module can provide temperature information using the
READ_TEMPERATURE_1 command. The command returns
two bytes of data in the linear format. The upper five bits [7:3]
of the high data byte form the two’s complement
representation of the exponent, which is fixed at –2 (decimal).
The remaining 11 bits are used for two’s complement
representation of the mantissa.
Note that the module’s temperature sensor is located close
to the module hot spot TH1 (see Thermal Considerations).and
is subjected to temperatures higher than the ambient air
temperature near the module. The temperature reading will
be highly influenced by module load and airflow conditions.
Reading the Status of the Module using the PMBus
The module supports a number of status information
commands implemented in PMBus. However, not all features
are supported in these commands. A X in the FLAG cell
indicates the bit is not supported.
STATUS_WORD : Returns two bytes of information with a
summary of the module’s fault/warning conditions.
High Byte
Bit Position
Flag
Default Value
15
VOUT fault
0
14
IOUT fault or warning
0
13
Input Voltage fault
0
12
X
0
11
POWER_GOOD# (is negated)
0
10
X
0
9
X
0
8
X
0
Bit Position
7
6
5
4
3
2
1
0
Low Byte
Flag
X
OFF
VOUT Overvoltage
IOUT Overcurrent
VIN Undervoltage
Temperature
CML (Comm. Memory Fault)
X
Default Value
0
0
0
0
0
0
0
0
STATUS_VOUT : Returns one byte of information relating to
the status of the module’s output voltage related faults.
Bit Position
Flag
Default Value
7
VOUT OV Fault
0
6
X
0
5
X
0
4
X
0
3
X
0
2
X
0
1
X
0
0
X
0
STATUS_IOUT : Returns one byte of information relating to the
status of the module’s output currentrelated faults.
Bit Position
Flag
Default Value
7
IOUT OC Fault
0
6
X
0
5
IOUT OC Warning
0
4
X
0
3
X
0
2
X
0
1
X
0
0
X
0
STATUS_INPUT : Returns one byte of information relating to
the status of the module’s input voltage related faults.
Bit Position
Flag
Default Value
7
VIN OV Fault
0
6
X
0
5
X
0
4
VIN UV Fault
0
3
Module Off (Low VIN)
0
2
X
0
1
X
0
0
X
0
STATUS_TEMPERATURE : Returns one byte of information
relating to the status of the module’s temperature related
faults.
Bit Position
Flag
Default Value
7
OT Fault
0
6
OT Warning
0
5
X
0
4
X
0
3
X
0
2
X
0
1
X
0
0
X
0
STATUS_CML : Returns one byte of information relating to the
status of the module’s communication related faults.
Bit Position
Flag
Default Value
7
Invalid/Unsupported
Command
0
6
Invalid/Unsupported Data
0
5
Packet Error Check Failed
0
4
X
0
3
X
0
2
X
0
1
X
0
0
X
0
May 9, 2013
©2012 General Electric Company. All rights reserved.
Page 19