Naos Raptor 40A Non Isolated Power Module:
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 40A output current
Safety Considerations
For safety agency approval the power module must
be installed in compliance with the spacing and
separation requirements of the end-use safety agency
standards, i.e., UL 60950-1, CSA C22.2 No. 60950-1-
03, and VDE 0850:2001-12 (EN60950-1) Licensed.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power
module has extra-low voltage (ELV) outputs when all
inputs are ELV.
The input to these units is to be provided with a fast-
acting fuse with a maximum rating of 30A in the
positive input lead.
Feature Descriptions
Remote On/Off
The Naos Raptor 40A power modules feature a
remote On/Off capability with positive logic. If not
using the On/Off pin, leave the pin open (the module
will be ON. The On/Off signal (VOn/Off) is referenced to
ground.
During a Logic High on the On/Off pin, the module
remains ON. During Logic-Low, the module is turned
OFF.
MODULE
5V
100K
ON/OFF
2.2K
47K
2K
2.2K
47K
GND
2K
ENABLE
Figure 41. Remote On/Off Implementation.
Overcurrent Protection
To provide protection in a fault (output overload)
condition, the unit is equipped with internal
current-limiting circuitry and can endure current
limiting continuously. At the point of current-limit
inception, the unit enters hiccup mode. The unit
operates normally once the output current is brought
back into its specified range. The typical average
output current during hiccup is 10% of Io,max.
Over Temperature Protection
To provide protection in a fault condition, the unit is
equipped with a thermal shutdown circuit. The unit will
shut down if the overtemperature threshold of 127ºC
is exceeded at the thermal reference point Tred. The
thermal shutdown is not intended as a guarantee that
the unit will survive temperatures beyond its rating.
Once the unit goes into thermal shutdown, it will then
wait to cool before attempting to restart.
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout
limit, module operation is disabled. The module will
begin to operate at an input voltage above the
undervoltage lockout turn-on threshold.