75 Watt Swithing Power Supply
Features:
∎ 75 Watt Modular Power Supply
∎ Universal AC Input Range (90-264 VAC)
∎ Optional Power Factor Correction (CCH Models)
∎ Low Profile for 1U High Applications
∎ Meets VDE/FCC Class “B” EMI
∎ Industry Standard 3 x 5” Footprint
∎ Total Power Overload Limit Protection
∎ Over-Current Protection
∎ International Safety Certifications - UL, CSA, TUV & CE Mark (LVD)
FEATURES
PFC Compliant to EN61000-3-2
Input Protection per EN61000-4
Economical
Flexibility With Options
SPECIFICATIONS
Input Voltage Range
Input Current Maximum
Inrush Current
Input Protection
Power Factor
Efficiency
EMI
Output Power
Over-Power Limit
Over-Load Protection
Over-Voltage Protection
Voltage Adjustment Range
Regulation
Ripple & Noise
Operating Temperature
Shock & Vibration
Dimensions
Safety Approvals
BENEFITS
Supports global use of power supply
Designed to operate in harsh environmental conditions
Lowered system costs
Custom capability without NRE & long lead-times
KEY MARKET SEGMENTS & APPLICATIONS
∎ Automation Equipment
∎ Industrial Applications
∎ Computer Peripherals
∎ Networking / Datacom
∎ Test Equipment
∎ POS Equipment
∎ Gaming
75 Wat Switching Power Supply
Universal AC Input Range (90-264 VAC, 47-63 Hz
1.25A (max continuous, 85VAC Full Load)
20A @ 115 VAC / 32A @ 230 VAC (typical)
Single fuse (2.0 or 3.5A / 250VAC / HB Type)
Passive PFC for EN61000-3-2 Class D Compliance
70% typical (65% minimum) @ 115 VAC (measured at full load)
FCC and VDE Level “B” (Conducted)
75 Watts Continuous
Set at 90W typical by sensing the primary input current
V1 & V2 of CCH74 Models / V1 of CCH75 Models only. 110 - 135% of max Iout. Output recovers when fault is removed
V1 & V2 of CCH74Models / V1 of CCH75Models only. Trip point set at 116%- 130%of V1 or V2. To reset, cycle input power
±5% of V1 only, V2 / V3 is fixed
±2% max of V1, V2 / V3 is ±5% max
1% pk-pk maximum @ 20MHz
Full load from 0 to 50ºC. Derates linearly from 50ºC to 70ºC at 2.5% per ºC, 8 CFM Required for Full Power
Per MIL STD-810E per 516.4 Part IV
3.00 x 5.00 x 1.95” (76.2mm x 125.7mm x 38.1mm) for standard open frame model
UL 1950, CSA 22.2 No. 950 & 234, TUV (EN60950), CE Mark & CB Report
MODEL
CCH75F1
CCH74C3
CCH74D3
CCH74H3
CCH75K3
CCH75Q3
rev 091201
Lineage Power
3000 Skyline Dr.
Mesquite, TX 75149
Phone: (972) 284-2000
Vout
12
+3.3
+3.3
+5.1
+5.1
+5.1
V1 OUTPUT
Io Min Io Max
0 .60
6.25
0.60
9.00
0.90
9.00
0.90
9.00
0.90
9.00
0.90
9.00
Io Peak
8.00
10.00
10.00
10.00
10.00
10.00
Vout
+5.1
+5.1
+3.3
+12
+15
V2 OUTPUT
Io Min Io Max
Io Peak
Vout
0.40
N/S
3.50
+5
0.20
N/S
2.00
+12
0.20
N/S
3.50
+12
0.30
3.00
3.50
-12
0.30
3.00
3.50
-15
Lineage Power
2841 Dow Avenue
Tustin, CA 92780 USA
Phone: (714) 544-6665
Lineage Power (China)
1353 Chenqiao Road, Shanghai Sengpu Industrial Park
Shanghai, 201401 China
Phone: 021 6710 8910
V3 OUTPUT
Io Min Io Max
Io Peak
0.10
1.00
N/S
0.10
1.00
N/S
0.10
1.00
N/S
0.10
1.00
1.50
0.10
1.00
1.50