English
Language : 

CAR1612FP Datasheet, PDF (1/2 Pages) Lineage Power Corporation – 1600 Watt +12V Front End Power Supply
by Lineage Power
CAR1612FP Series
1600 Watt +12V Front End Power Supply
Features:
∎ Compact 1U Profile
∎ High Efficiency design optimized for mid to light load applications
∎ Constant Current Characteristic
∎ N+1 Redundancy with Hot Plug Capability
∎ High Power Density (20W/in3)
∎ 3.3VSB, Active Load Sharing, I²C and PMBus standard Interface
∎ Remote On/Off and Remote Sense functions
PLATINUM
FEATURES
High Power Density 20W/in3
Load Sharing & Fault Tolerant
Automatic Fan Speed Control
System Scalability up to 6.4kW
Universal Input & International
Certifications
SPECIFICATIONS
Input Voltage Range
Input Current Maximum
Inrush Current
Input Protection
Power Factor
Efficiency
Output Power
Output Voltage Range
Output Current
Standby Bias Voltage
Voltage Regulation
Output Ripple & Noise
Transient Response
Hold-Up Time
Remote On/Off
Current Limit Protection
Short Circuit Protection
Over Voltage Protection
Operating Temperature
Over Temperature Protection
EMI
LED Indicators
Analog Status & Control
Digital Status & Control
Shock & Vibration
Dimensions
Weight
Safety Approvals
Options
Lineage Power
3000 Skyline Dr. P: (972) 284-2000
Mesquite, TX 75149 F: (972) 284-2000
rev 100603
BENEFITS
More system space for application circuits and hardware
Excellent reliability in N+1 operation
Reduces audible noise and increases reliability
Allows flexibility with minimum investment
Reduces logistical costs
KEY MARKET SEGMENTS & APPLICATIONS
∎ Distributed Power ∎ Blade Servers
∎ Mid-End Servers ∎ Network Equipment
∎ Network Attached Storage
∎ Storage Area Networks
1600 Watt +12V Front End Power Supply
85-264 VAC, 47-63 Hz, derate to 1200W for <180VAC Input
10.5A @ 180VAC / 14.3A @ 100VAC, Full Load (max)
40A max. cold start (per ETS 300 132-1 and Bellcore specifications)
20 Amp / 250 VAC
0.99 typical at full load, complies with IEC555, EN60555-2, EN61000-3-2
Up to 94.5% at 50% Load and 230VAC Operation
1600W at High Line Operation (180-264 VAC), 1200W at Low Line Operation (85-132 VAC)
10.8~13.2 VDC with remote programming
134A @ 12Vout / 230VAC Operation, 100A @ 12Vout / 110VAC Operation
3.3VSB@1A (optional 5Vsb)
±2% of Vnom for any combination of line, load and temperature
1% (pk-pk) @ 20MHz with 0.1µF ceramic and 10µF Tantalum caps at the output
5% max deviation Recovery time 300μs @ 50% load step and di/dt < 1A/μs
12ms at 1600W (typical) @ 220Vac (Early Warning: 2ms)
ON if >3V or open; OFF if <1V (max. sink 1mA) Open collector type
Adjustable via I²C interface or PMBus, Constant current characteristic & power limited to 1600W or 1200W (<180VAC input)
Self protected with auto recovery
Trip level >+14.8Vdc ± 1V, Reset condition by recycling the AC input or applying Remote ON/OFF
-10°C to +70°C. power derating above 50°C at 2.5%/°C
Non-Latching, thermal shutdown point is set for 125°C and recovery point is 110°C
FCC-B & EN55022-B with specified filter or at rack level, GR-1089-CORE
AC OK (Green) / DC OK (Green) / Thermal Alarm (Orange) / Fault (Red), “All on one LED” Tri-color LED
Voltage Programming (V Prog), Load sharing (I Share), Remote On/Off, Current Monitor (I Monitor), AC OK, DC OK,
Temperature Warning, Fault, PS Present, Module Enable,
I2C Option and PMBus Option, see detailed specification for details
NEBS GR-63-CORE Level 3
12.45 x 4.00 x 1.61” / 316.23 x 101.6 x 41.91mm
4.28 lb. / 1.94 kg.
IEC/UL/CSA/EN60950-1, CE Mark (LVD), TUV
5VSB Output, Bezel
Lineage Power
2841 Dow Avenue P: (714) 544-6665
Tustin, CA 92780 USA F: (714) 838-4742
Lineage Power (China)
1353 Chenqiao Road, Shanghai Sengpu Industrial Park
Shanghai, 201401 China
P: 021 6710 8910
w w w. L i n e a g e P o w e r. c o m