English
Language : 

ATL010A0X43-SR Datasheet, PDF (1/21 Pages) Lineage Power Corporation – 9 - 18Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current
Data Sheet
April 1, 2008
ATL010A0X43-SR Non-Isolated Power Modules 12Vdc, Programmable
9 – 18Vdc input; 0.75Vdc to 5.5Vdc Output; 10A Output Current
RoHS Compliant
Applications
ƒ Distributed power architectures
ƒ Intermediate bus voltage applications
ƒ Telecommunications equipment
ƒ Servers and storage applications
ƒ Networking equipment
Features
ƒ Compliant to RoHS EU Directive 2002/95/EC (-Z
versions)
ƒ Compliant to RoHS EU Directive 2002/95/EC with
lead solder exemption (non-Z versions)
ƒ Flexible output voltage sequencing EZ-SEQUENCE
ƒ Delivers up to 10A of output current
ƒ High efficiency – 93% at 3.3V full load (VIN = 12.0V)
ƒ Small size and low profile:
33.00 mm x 13.46 mm x 8.28 mm
(1.300 in x 0.530 in x 0.326 in)
ƒ Low output ripple and noise
ƒ High Reliability:
Calculated MTBF = 15 M hours at 25oC Full-load
ƒ Output voltage programmable from 0.75 Vdc to 5.5
Vdc via external resistor
ƒ Line Regulation: 0.3% (typical)
ƒ Load Regulation: 0.4% (typical)
ƒ Temperature Regulation: 0.4% (typical)
ƒ Remote On/Off
ƒ Remote Sense
ƒ Output overcurrent protection (non-latching)
ƒ Overtemperature protection
ƒ Wide operating temperature range (-40°C to 85°C)
ƒ UL* 60950-1Recognized, CSA† C22.2 No. 60950-1-
03 Certified, and VDE‡ 0805:2001-12 (EN60950-1)
Licensed
ƒ ISO** 9001 and ISO 14001 certified manufacturing
facilities
Description
The ATL010A0X43-SR power modules are non-isolated dc-dc converters that can deliver up to 10A of output
current with full load efficiency of 93% at 3.3V output. These modules provide a precisely regulated output voltage
programmable via an external resistor from 0.75Vdc to 5.5Vdc over a wide range of input voltage (VIN = 9 – 18Vdc).
The ATL010A0X43-SR series has a sequencing feature, EZ-SEQUENCETM that enables designers to implement
various types of output voltage sequencing when powering multiple voltages on a board. Their open-frame
construction and small footprint enable designers to develop cost- and space-efficient solutions. In addition to
sequencing, standard features include remote On/Off, remote sense, output voltage adjustment, over current and
over temperature protection.
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Association.
‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
Document No: DS05-008 ver.1.21
PDF name: atl010a0x43-sr_ds.pdf