English
Language : 

APTS050A0X Datasheet, PDF (1/20 Pages) Lineage Power Corporation – GigaTLynxTM Non-isolated Power Modules
Data Sheet
March 30, 2011
GigaTLynxTM Non-isolated Power Modules:
4.5Vdc – 14Vdc input; 0.7Vdc to 2Vdc, 50A Output
Applications
 Distributed power architectures
 Intermediate bus voltage applications
 Industrial applications
 Telecommunications equipment
Vin+
+
CI2
CI1
VIN
PGOOD
VOUT
SENSE+
SEQ
MODULE
ON/OFF TRIM+
TRIM-
GND SESNESNES-E-
Vout+
RTUNE
CTUNE
CO1
+
CO2
RTrim
Features
 Compliant to RoHS EU Directive 2002/95/EC
(-Z versions)
 Compliant to RoHS EU Directive 2002/95/EC with
lead solder exemption (non-Z versions)
 Input voltage from 4.5Vdc to 14Vdc
 Output voltage programmable from 0.7 Vdc to
2.0Vdc via external resistor
 Output current up to 50A
 Tunable control loop for fast transient response
 True differential remote sense
 Negative remote On/Off logic
 Output voltage sequencing (EZ-SEQUENCE TM)
 Output over current protection (non-latching)
 Over temperature protection
 Monotonic startup under pre-bias conditions
 Parallel operation with active current sharing
 Small size and low profile:
33 mm x 22.9 mm x 10 mm (max.)
(1.3 in x 0.9 in x 0.393 in (max.))
 Wide operating temperature range (-40°C to 85°C)
 UL* 60950-1, 2nd Ed. Recognized, CSA† C22.2 No.
60950-1-07 Certified, and VDE‡ (EN60950-1, 2nd
Ed.) Licensed
 ISO** 9001 and ISO 14001 certified manufacturing
facilities
Description
The GigaTLynxTM series of power modules are non-isolated dc-dc converters that can deliver up to 50A of output
current. These modules operate over a wide range of input voltage (VIN = 4.5Vdc-14Vdc) and provide a precisely
regulated output voltage from 0.7Vdc to 2.0Vdc, programmable via an external resistor. Features include remote
On/Off, adjustable output voltage, over current and over temperature protection, output voltage sequencing and
paralleling. A new feature, the Tunable LoopTM, allows the user to optimize the dynamic response of the converter
to match the load with reduced amount of output capacitance leading to savings on cost and PWB area.
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Association.
‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
Document No: DS010-005 ver. 1.1
PDF name: APTS050A0X.pdf