English
Language : 

ACE4000 Datasheet, PDF (1/2 Pages) Lineage Power Corporation – 3 Bay / 12 Kilowatt Power Shelf
Features:
• 3U High
• Up to 12,000W in a 19” Rack
• Single & Three Phase Input Models
• Fits 3 Hot-Plug / N+1 Redundant Rectifiers
• Current Sharing and Remote Sensing
• World-wide safety approvals
• Optional 1U Controller Available
ACE4000
3 Bay / 12 Kilowatt Power Shelf
FEATURES
Single wire current sharing
Constant power characteristic
No Minimum Load
Optional 1U High Controller
BENEFITS
Provide system stress balancing and increases reliability
Better suited for battery charging applications
Eliminates need for pre-load resistors. Reduces cost of ownership.
Addresses telecom application requirements for redundant operation
KEY MARKETS & APPLICATIONS
• Central Office
• Telecom Access Nodes
• Satellite Hubs
• Broadband Switchers
• XDSL Access Networks
• Cellular Base Stations
• Wireless
• RF Amplifiers
• PCS Installations
• Factory Automation
SPECIFICATIONS
Rack Model Number
Rectifier Module Part Number
Voltage Range
Output Current
Input Voltage
Maximum Input Current (per module)
Maximum Output Power
AC Input Feeds
Input Protection
Efficiency
Regulation (Line & Load)
Ripple & Noise
Load Sharing
DC Bus
Status Indicators
Alarm Signals
Battery Interface
Temperature Range
Shock & Vibration
EMI / EMC
Safety Approvals
Dimensions
12,000 Watt Power Shelf for CAR4000 Front End Modules
ACE403
ACE403N
ACE433
ACE433N
CAR4010L1-1A
CAR4010K1-1A
CAR4010L1N-1A
CAR4010K1N-1A
CAR4030L1-1A
CAR4030K1-1A CAR4030L1N-1A CAR4030K1N-1A
+43.2~52.8 VDC +21.6~26.4 VDC -43.2~52.8 VDC
-21.6~26.4 VDC +43.2~52.8 VDC +21.6~26.4 VDC -43.2~52.8 VDC -21.6~26.4 VDC
250A @ +48Vout 500A @ +24Vout 250A @ -48Vout
500A @ -24Vout 250A @ +48Vout 500A @ +24Vout 250A @ -48Vout 500A @ -24Vout
Single Phase 180-264 VAC / 47-63 Hz
Three Phase 180-264 VAC / 47-63 Hz
25A @ Full Load and 180 VAC Operation (per module)
15A per phase @ Full Load and 180 VAC Operation (per module)
12,000 Total Output Power (8,000 Watts Redundant Output Power)
Individual Input Feeds for each rectifier for 4mm2 cable
Each CAR rectifier module is equipped with it's own internal fuse
90% typical at 230VAC
+/- 0.5% of V1
1% of V1 (pk-pk) - using 10µF tantalum cap. and 0.1µF ceramic cap.
Single wire. +/- 5% of nominal current
Rectifiers connected in parallel. Floating bus with common "+". Maximum current is 250A
DC Good and Temperature OK (Green), AC Good (Amber)
Over Temperature, Over/Under Voltage, No Power, Module not present
RJ45 signal connector per rectifier. RS232 for programming via laptop (with Controller).
0 to 50°C at rated output power. Derates linearly to 60°C at 2.2% per °C
Per MIL STD-810F, NEBS Compliant to GR 63 Core
Meets EN61000-3-2, -3 CISPR22 and FCC Part 15 Class A, Bellcore GR-1089-Core
UL: 478, 1012, 1950; CSA 22.2 No. 650; IEC: 380, 435, 950; VDE: 0804, 0806; & CE Mark (LVD)
Chassis Measures 18.00”/457.2mm (depth) x 17.165”/436.0mm (width) x 5.12”/132.1mm (height)
rev 100506
Lineage Power
3000 Skyline Dr.
Mesquite, TX 75149
Phone: (972) 284-2000
Lineage Power
2841 Dow Avenue
Tustin, CA 92780 USA
Phone: (714) 544-6665
Lineage Power (China)
1353 Chenqiao Road, Shanghai Sengpu Industrial Park
Shanghai, 201401 China
Phone: 021 6710 8910
w w w. l i n e a g e p o w e r. c o m / o e m