English
Language : 

LA150-P_12 Datasheet, PDF (3/3 Pages) LEM – Current Transducer
Dimensions LA 150-P (in mm)
Connection
Mechanical characteristics
●● General tolerance
± 0.5 mm
●● Primary through-hole
13.5 x 10 mm
●● Fastening & connection of secondary 3 pins 0.6 x 0.6 mm
Recommended PCB hole
Ø 1.1 mm
Remarks
●● IS is positive when IP flows in the direction of the arrow.
●● Temperature of the primary conductor should not exceed
100°C.
●● Dynamic performances (di/dt and response time) are
best with a single bar completely filling the primary hole.
●● This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
14December2012/version 3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
Page 3/3
www.lem.com