Absolute maximum ratings (not operating)
Parameter
Symbol
Maximun peak primary current (not operating)
Primary nominal DC or current rms
Maximun supply voltage (not operating)
Secondary maximum admissible power
Ambient operating temperature
Ambient storage temperature
Electrostatic discharge voltage
IP max
IPN
VC max
PS max
TA
TS
VESD
Maximum admissible vibration
γ
Rms voltage for AC insulation test 50 Hz, 1 min
Creepage distance
Vd
dCp
Clearance
dCI
Unit
A
A
V
mW
°C
°C
V
m.s -2
V
mm
mm
Specification
Defined by busbar to have T° ≤ 150°C
Defined by busbar to have T° ≤ 150°C
7
150
-40 < TA < 125°C
-40 < TS < 125°C
2000
100
1500
1.67
1.80
Conditions
see page 5/5
see page 5/5
CTI=425
Operating characteristics
Parameter
Symbol
Primary current, measuring range
Supply voltage 1)
Output voltage (Analog)
Sensitivity
Offset voltage
Current consumption
Load resistance
Output internal resistance
IPM
VC
VOUT
G
VO
IC
RL
ROUT
Sensitivity error
Electrical offset
Magnetic offset
IOE
Average temperature coefficient of
VOE
Average temperature coefficient of G
Linearity error
Response time
Frequency bandwidth 2)
Output voltage noise peak-peak
Output voltage noise rms
εG
IOE
VOE
IOM
VOM
TCIOEAV
TCVOEAV
TCGAV
ε
L
tr
BW
Vno p-p
Vno rms
Unit
Specification
Min Typical Max
Electrical Data
A
-100
100
V
4.75
5.00
5.25
V
VOUT = (VC/5) x (2.5 +0.02 x IP )
V/A
0.0196 0.02
0.0204
V
2.481
2.5
2.519
mA
-
15
20
ΚΩ
2
-
-
Ω
-
-
10
Performance Data (1)
%
-2.0
± 0.7
2.0
A
-0.7
± 0.25
0.7
mV
-14
±5
14
A
-0.25 ± 0.15
0.25
mV
-5
±3
5
mA/°C
-7
±4
7
mV/°C -0.14 ± 0.08
0.14
%/°C
-0.04 ± 0.02
0.04
% IP
-1.0
± 0.2
1.0
µs
-
15
20
kHz
20
-
-
mV
-
35
43
mV
-
-
4
Conditions
@ - 40°C < T° < 125°C
@ - 40°C < T° < 125°C
@ - 40°C < T° < 125°C
@ TA = 25°C; VC = 5 V
@ VC = 5 V; TA = 25°C; IP = 0 A
@ - 40°C < T° < 125°C; 4.75 V < VC < 5.25 V
@ TA = 25°C, VC = 5 V; Gth = 0.02 V/A
@ VC = 5.00 V; TA = 25°C
@ After excursion to ± IP; TA = 25°C
@ - 40°C < T° < 125°C; VC = 5.00 V
@ - 40°C < T° < 125°C; VC = 5.00 V
@ IP; VC = 5.00 V, TA = 25°C
@ di/dt = 50 A/µs; IT = 60 A
@ -3 dB; IT = 20 A rms
@ TA = 25°C; 0 Hz < f < 1 MHz
@ TA = 25°C; 0 Hz < f < 1 MHz
3.5
3
Notes: 1) The output voltage VOUT is fully ratiometric. The
offset and sensitivity are dependent on the supply
2.5
voltage VC relative to the following formula:
2
1.5
IP =  VOUT − VC  × 1 × 5
with G in (V / A)
1

2  G VC
0.5
0
-100
-80
-60
-40
-20
0
@25
-20°C < T° < 85°C
- 40°C < T° < 125°C
20
40
60
80
100
Prim ary current Ip (A)
2) Small signal only to avoid excessive heating of
the busbar, the magnetic core and the ASIC.
Page 3/5