FHS 40-P/SP600
0 - 100A
Notes: All parameters are for the VC range from 4.5 V to 5.5 V, and TA = - 40°C to + 125°C.
Typical values are for VC = 5 V; TA = 25°C. Values are for the application schematic shown in figure 6.
Electrical data
Parameter
Symbol
Unit
Min
Typ
Max
Supply voltage
VC
Current consumption
IC
Output voltage in a flux density B
Magnetic flux density measuring range
Linearity error
Sensitivity, referred to magnetic field
Sensitivity - VC influence
Temperature coefficient of GB
Reference voltage (Internal reference used as output)
Regulation VC
Output impedance VREF
Temperature coefficient of VREF
Temperature coefficient of VREF
Reference voltage (External reference used as input)
Additional sensitivity error
Additional electrical offset voltage
Electrical offset voltage VOUT - VREF
Electrical offset voltage VOUTFast - VREF
Temperature coefficient of VOE and VOEFast
Offset - VC influence (VOE and VOEFast)
Output resistance VOUT
Output resistance VOUTFast
VOUT
BM
εL
GB
TCG
VREF
TCVREF
TCVREF
VREF
VOE
VOEFast
TCVOE
ROUT
ROUTFast
Output current magnitude VOUT
IOUT
V
mA
µA
V
mT
%
mV/mT
% of VC = 5 V value
ppm/°C
V
mV/V
Ω
ppm/°C
ppm/°C
V
%/V
mV/V
mV
mV
mV/°C
mV
Ω
Ω
mA
Output current magnitude VOUTFast
Maximum output capacitive loading
Standby pin “0” level
Standby pin “1” level
Time to switch from standby to normal mode
Output voltage noise VOUT and VOUTFast
Internal Clock feed through VOUT
Internal Clock feed through VOUTFast
Reaction time VOUT
Response time VOUT
Reaction time VOUTFast
Response time VOUTFast
Frequency bandwidth VOUT
IOUTFast
CL
Vno
tra
tr
traFast
trFast
BW
mA
nF
V
V
µs
µVrms/√Hz
µVrms
µVrms
µs
µs
µs
µs
kHz
Frequency bandwidth VOUTFast
BWFast
kHz
4.75
5
5.5
15
19
20
VREF + VOE + (G x B)
±3.3
-1.5
±0.4
1.5
582
-1
-350
2.480
-5
150
-80
-100
1.5
-1
-40
-10
-0.15
-10
30
50
5
10
-0.3
VC-0.5
600
2.5
200
±50
60
15
400
1600
105
45
120
55
618
1
350
2.52
5
250
80
100
2.8
1
20
10
0.15
10
5
10
18
+0.5
VC+0.3
3
5
3
3
Conditions
4.5 V possible but limits
measurement range
Operating mode
Standby mode
Simplified model
VC = 5 V
GB = 600 mV/mT,
B = ± 3.3, VC = 5 V
@ 25°C, VC = 5 V
@ 25°C, @ VC = 5 V ± 10%
Refered to 25°C; 3 sigma limits
@ 25°C, VC = 5 V
@ 25°C, VC = 5 V ± 10%
25°C - 125°C; 3 sigma limits
-40°C - 25°C; 3 sigma limits
Relative to 2.5 V
Relative to 2.5 V
@ 25°C, B = 0; VC = 5 V
@ 25°C, B = 0; VC = 5 V
Refered to 25°C and VREF; 3 sigma limits
@ 25°C, VC = 5 V ± 10%
DC
DC
As source
As sink
As source
As sink
4.7 nF recommended
For standby mode
90 % of correct output
f = 1500 Hz - 100 Hz
(f = 500 kHz typ)
(f = 500 kHz typ)
Input signal rise time 1 µs
Input signal rise time 1 µs
Input signal rise time 1 µs
Input signal rise time 1 µs
@ -3 dB (Kit 9)
@ -1 dB (Kit 9)
@ -3 dB (Kit 9)
@ -1 dB (Kit 9)
100727/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 3/18
www.lem.com