English
Language : 

LAH25-NP_06 Datasheet, PDF (2/2 Pages) LEM – Current Transducer
Dimensions LAH 25-NP (in mm. 1 mm = 0.0394 inch)
Bottom view
Connection
Left view
Front view
Number
of primary
turns
Primary current
nominal maximum
IPN [ A ] IP [ A ]
Nominal
output current
ISN [ mA ]
Turns
ratio
KN
1
25
55
25
1 : 1000
2
12
27
24
2 : 1000
3
8
18
24
3 : 1000
Primary
resistance
R P [ mΩ ]
Primary insertion
inductance
LP
[ µH ]
0.18
0.012
0.81
0.054
1.62
0.110
Recommended
PCB c o n n e c t i o n s
3 2 1 IN
OUT 4 5 6
3 2 1 IN
OUT 4 5 6
3 2 1 IN
OUT 4 5 6
Mechanical characteristics
• General tolerance
• Fastening & connection of primary
Recommended PCB hole
• Fastening & connection of secondary
Recommended PCB hole
± 0.2 mm
6 pins 1 x 0.8 mm
1.5 mm
3 pins 0.7 x 0.6 mm
1.2 mm
Remarks
• IS is positive when IP flows from terminals 1, 2, 3 (IN) to
terminals 6, 5, 4 (OUT).
• The jumper temperature and PCB should not exceed 100°C.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
LEM
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
060213/5
page 2/2
www.lem.com