Electrical data
Primary nominal
r.m.s. current
IPN (A)
100
200
500
1000
Type
RH 100-S
RH 200-S
RH 500-S
RH 1000-S
VOUT
VC
Vd
IC
RIS
RL
Output voltage(r.m.s) @ ± IPN, RL = 10 kâ¦, TA = 25°C 4
V
Supply voltage (± 5 %)
±15
V
R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn > 2.5
kV
Current consumption
15
mA
Isolation resistance@ 500 V DC
> 500
Mâ¦
Load resistance
⥠100
Kâ¦
Accuracy-Dynamic performance data
εL
V
OE
ε VOT
TC
G
tr
f
Linearity (0 .. ± IPN)
Electrical offset voltage, T = 25°C
A
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
Frequency bandwidth (±3 dB)
⤠±0.5 % of IPN
±5
mV
⤠±0.3 mV/K
±0.03 %/K
1
µs
20Hz .. 100KHz
General data
T
Ambient operating temperature
A
TS
Ambient storage temperature
m
Mass
Min. internal creepage distance/clearance
-10 .. +75 °C
-15 .. +80 °C
45
g
ø20±0.5 m m
Features
⢠No magnetic core
⢠Rogowski Coil principle
⢠Highly accurate integration circuit
⢠Voltage output
Advantages
⢠Wide sensing range
⢠Wide frequency range
⢠Quick response
⢠No hysteresis error
⢠No insertion impedance
⢠Small size and lightweight
Applications
⢠Observing complicated current
waveforms
⢠High speed and high current
sensing such as IGBT
⢠Welding
⢠Power unit
⢠Electric power regulator
⢠Discharge tube
⢠Antenna
⢠Monitoring for irruptive current
Notes :
LEM Components
031020/0
www.lem.com
|
▷ |