English
Language : 

LV200-AW_03 Datasheet, PDF (1/2 Pages) LEM – LV200-AW
Voltage Transducer LV 200-AW/2
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
IPN = 20 mA
VPN = 100 .. 2500 V
Electrical data
I PN Primary nominal r.m.s. current
IP
Primary current, measuring range
RM Measuring resistance
20
mA
0 .. ± 40
mA
RM min
RM max
with ± 15 V
with ± 24 V
@ ± 20 mA max
@ ± 40 mA max
@ ± 20 mA max
@ ± 40 mA max
0
90
Ω
0
25
Ω
60
170 Ω
60
65
Ω
ISN Secondary nominal r.m.s. current
IS
Secondary current @ IP max
KN Conversion ratio
VC Supply voltage (± 10 %)
IC
Current consumption
Vd
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
100
mA
200
mA
10000 : 2000
± 15 .. 24
V
30 (@±24V )+IS m A
6 1)
kV
1 2)
kV
Ve
R.m.s.voltage for partial discharges extinction @10 pC 2.5
kV
Accuracy - Dynamic performance data
Features
• Closed loop (compensated) voltage
transducer using the Hall effect
• Insulated plastic case recognized
according to UL 94-V0
• Accessible electronic circuit
• Shield between primary and
secondary circuit.
Principle of use
• For voltage measurements, a current
proportional to the measured voltage
must be passed through an external
resistor R 1 which is selected by the
user and installed in series with the
primary circuit of the transducer.
εX G
L
Overall Accuracy @ IPN , TA = 25°C
Linearity error
IO
Offset current @ IP = 0, TA = 25°C
IOT
Thermal drift of IO
- 25°C .. + 70°C
tr
Response time 3) @ 90 % of VPN
General data
± 0.5
%
< 0.1
%
Typ Max
± 0.3 m A
± 0.4 ± 0.7 m A
20 .. 100
µs
Advantages
• Excellent accuracy
• Very good linearity
• Low thermal drift
• High immunity to external
interference
Applications
TA
Ambient operating temperature
TS
Ambient storage temperature
R P Primary coil resistance @ TA = 25°C
R S Secondary coil resistance @ TA = 70°C
m Mass
Standards
- 25 .. + 70
°C
- 40 .. + 85
°C
420
Ω
40
Ω
1.6
kg
EN 50178 (01.10.97)
Notes : 1) Between primary and secondary + shield
2) Between secondary and shield
3) R 1 = 50 kΩ (L/R constant, produced by the resistance and inductance
of the primary circuit)
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Power supplies for welding
applications .
030916/8
LEM Components
w w w.lem.com