English
Language : 

LV100-2500 Datasheet, PDF (1/2 Pages) LEM – Voltage Transducer LV 100-2500
Voltage Transducer LV 100-2500
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
VPN = 2500 V
Electrical data
V
Primary nominal r.m.s. voltage
PN
VP Primary voltage, measuring range
I
Primary nominal r.m.s. current
PN
RM Measuring resistance
with ± 15 V
@ ± 2500 V max
@ ± 3750 V
max
ISN
Secondary nominal r.m.s. current
K N Conversion ratio
VC Supply voltage (± 5 %)
IC
Current consumption
Vd
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
Accuracy - Dynamic performance data
X
Overall Accuracy @ V , T = 25°C
εG
L
Linearity
PN A
IO
Offset current @ IP = 0, TA = 25°C
I
Thermal drift of I
OT
O
0°C .. + 70°C
tr
Response time @ 90 % of VP max
General data
T
Ambient operating temperature
A
TS
Ambient storage temperature
N
Turns ratio
P
Total primary power loss
R
Primary resistance @ T = 25°C
1
A
R S Secondary coil resistance @ TA = 70°C
m
Mass
Standards 1)
2500
V
0 .. ± 3750
V
4
mA
RM min
RM max
0
170 Ω
0
90
Ω
50
mA
2500 V / 50 mA
± 15
V
10 + IS
mA
9
kV
± 0.7
%
< 0.1
%
Typ Max
± 0.2 mA
± 0.2 ± 0.3 mA
170
µs
0 .. + 70
°C
- 25 .. + 85
°C
25000 : 2000
10
W
625
kΩ
60
Ω
850
g
EN 50178
Features
•Closed loop (compensated) voltage
transducer using the Hall effect
•Insulated plastic case recognized
according to UL 94-V0
•Primary resistor R 1 incorporated into
the housing.
Advantages
•Excellent accuracy
•Very good linearity
•Low thermal drift
•High immunity to external
interference.
Applications
•AC variable speed drives and servo
motor drives
•Static converters for DC motor drives
•Uninterruptible Power Supplies
(UPS)
•Power supplies for welding
applications.
Note : 1) A list of corresponding tests is available
LEM Components
981102/2
w w w .lem.com