English
Language : 

LTS6-NP_10 Datasheet, PDF (1/3 Pages) LEM – Current Transducer
Current Transducer LTS 6-NP
For the electronic measurement of currents: DC, AC, pulsed,
mixed with galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN =
6 At
16065
Electrical data
IPN
Primary nominal current rms
IPM
Primary current, measuring range
ÎP
Overload capability
VOUT Output voltage (Analog) @ IP
IP = 0
G
Sensitivity
NS
RL
R IM
TCR IM
VC
IC
Number of secondary turns (± 0.1 %)
Load resistance
Internal measuring resistance (± 0.5 %)
Temperature coefficient of R IM
Supply voltage (± 5 %)
Current consumption @ VC = 5 V
Typ
6
At
0 .. ± 19.2
At
250
At
2.5 ± (0.625·IP/IPN)V
2.5 1)
V
104.16 mV/A
2000
≥ 2
kW
208.33
W
< 50 ppm/K
5
V
28+IS2)+(VOUT/RL) mA
Features
●● Closed loop (compensated) multi-
range current transducer using
the Hall effect
●● Unipolar voltage supply
●● Isolated plastic case recognized
according to UL 94-V0
●● Compact design for PCB
mounting
●● Incorporated measuring
resistance
●● Extended measuring range.
Accuracy - Dynamic performance data
Advantages
X
Accuracy @ IPN, TA = 25°C
ε
L
Accuracy with RIM @ IPN, TA = 25°C
Linearity error
●● Excellent accuracy
± 0.2
%
●● Very good linearity
± 0.7
%
●● Very low temperature drift
< 0.1
%
●● Optimized response time
Typ Max
●● Wide frequency bandwidth
TCVOUT Temperature coefficient of VOUT @ IP= 0 - 10°C .. + 85°C 80 200 ppm/K
- 40°C .. - 10°C
250 ppm/K
●● No insertion losses
●● High immunity to external
TCG Temperature coefficient of G
- 40°C .. + 85°C
50 3) ppm/K
interference
VOM
Magnetic offset voltage @ IP = 0,
after an overload of 3 x IPN
5 x IPN
10 x IPN
± 0.5 mV
± 2.0 mV
± 2.0 mV
tra
tr
di/dt
Reaction time @ 10 % of IPN
Response time to 90 % of IPN step
di/dt accurately followed
< 100
< 400
> 15
ns
ns
A/µs
BW Frequency bandwidth (0 .. - 0.5 dB)
DC .. 100 kHz
(- 0.5.. 1 dB)
DC .. 200 kHz
●● Current overload capability.
Applications
●● AC variable speed drives and
servo motor drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
General data
(UPS)
●● Switched Mode Power Supplies
TA
Ambient operating temperature
TS
Ambient storage temperature
m
Mass
Standards
- 40 .. + 85
°C
- 40.. + 100 °C
10
g
EN 50178: 1997
(SMPS)
●● Power supplies for welding
applications.
Application domain
Notes: 1) Absolute value @ TA = 25°C, 2.475 < VOUT < 2.525
2) IS = IP/NS
3) Only due to TCRIM.
IEC 60950-1: 2001
●● Industrial.
Page 1/3
100915/18
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com