English
Language : 

LTS6-NP_06 Datasheet, PDF (1/3 Pages) LEM – Current Transducer
Current Transducer LTS 6-NP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 6 At
Electrical data
16065
I
Primary nominal current rms
PN
IPM Primary current, measuring range
ÎPDC Overload capability (direct current)
VOUT Output voltage (Analog) @ IP
IP = 0
N
Number of secondary turns (± 0.1 %)
S
R L Load resistance
R
Internal measuring resistance (± 0.5 %)
IM
TCRIM Temperature coefficient of R IM
V
Supply voltage (± 5 %)
C
IC
Current consumption @ VC = 5 V
Typ
6
At
0 .. ± 19.2
At
250
At
2.5 ± (0.625·IP/IPN) V
2.5 1)
V
2000
≥2
208.33
< 50
kΩ
Ω
ppm/K
5
V
28+ IS2)+(VOUT/RL) m A
Features
• Closed loop (compensated) multi-
range current transducer using the
Hall effect
• Unipolar voltage supply
• Compact design for PCB mounting
• Isolated plastic case recognized
according to UL 94-V0
• Incorporated measuring resistance
• Extended measuring range.
Accuracy - Dynamic performance data
Advantages
X
Accuracy @ IPN , TA = 25°C
εL
Accuracy with R IM @ IPN , TA = 25°C
Linearity error
TCVOUT Temperature coefficient of VOUT @ IP = 0 - 10°C .. + 85°C
- 40°C .. - 10°C
TCG Temperature coefficient of G
- 40°C .. + 85°C
V
Residual voltage @ I = 0,after an overload of 3 x I
OM
P
PN
5 x IPN
10 x I
PN
tra
t
r
di/dt
Reaction time @ 10 % of IPN
Response time to 90 % of I step
PN
di/dt accurately followed
BW Frequency bandwidth (0 .. - 0.5 dB)
(- 0.5 .. 1 dB)
± 0.2
± 0.7
< 0.1
Typ Maxi
80 200
250
50 3)
± 0.5
± 2.0
± 2.0
< 100
< 400
> 15
DC .. 100
DC .. 200
%
%
%
ppm/K
ppm/K
ppm/K
mV
mV
mV
ns
ns
A/µ s
kHz
kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
Insulating material group
m
Mass
Standards 4)
- 40 .. + 85
°C
- 40 .. + 100 °C
III a
10
g
EN 50178: 1997
• Excellent accuracy
• Very good linearity
• Very low temperature drift
• Optimized response time
• Wide frequency bandwidth
• No insertion losses
• High immunity to external
interference
• Current overload capability.
Applications
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies (UPS)
• Switched Mode Power Supplies (SMPS)
• Power supplies for welding
applications.
Application domain
IEC 60950-1 : 2001
• Industrial.
Notes: 1) Absolute value @ TA = 25°C, 2.475 < VOUT < 2.525
2) IS= IP/N S
3) Only due to TCR IM
4) Specification according to IEC 61000-4-3 are not guaranteed between
95 and 110 MHz (value higher by 5% than the specification).
Copyright protected.
061213/16
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3