Current Transducer LTS 25-NP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 25 At
Electrical data
16054
IPN
Primary nominal r.m.s. current
IP
Primary current, measuring range
VOUT Analog output voltage @ IP
IP = 0
N S Number of secondary turns (± 0.1 %)
R L Load resistance
RIM Internal measuring resistance (± 0.5 %)
TCRIM Thermal drift of R IM
VC Supply voltage (± 5 %)
IC
Current consumption @ VC = 5 V
Typ
Accuracy - Dynamic performance data
25
At
0 .. ± 80
At
2.5 ± (0.625·IP/IPN) V
2.5 1)
V
2000
≥2
kΩ
50
Ω
< 50
ppm/K
5
V
28+IS2)+(VOUT/RL)m A
X
Accuracy @ IPN , TA = 25°C
Accuracy with R @ I , T = 25°C
εL
IM
PN A
Linearity error
TCV Thermal drift of V @ I = 0
OUT
OUT
P
- 10°C .. + 85°C
- 40°C .. - 10°C
ε TC Thermal drift of the gain
G
- 40°C .. + 85°C
VOM Residual voltage @ IP = 0,after an overload of 3 x IPN
5xI
PN
10 x IPN
tra
t
r
di/dt
Reaction time @ 10 % of IPN
Response time @ 90 % of I
PN
di/dt accurately followed
f
Frequency bandwidth (0 .. - 0.5 dB)
(- 0.5 .. 1 dB)
General data
± 0.2
%
± 0.7
%
< 0.1
%
Typ Max
50 100 ppm/K
150 ppm/K
50 3) ppm/K
± 0.5
mV
± 2.0
mV
± 2.0
mV
< 100
< 400
> 60
DC .. 100
DC .. 200
ns
ns
A /µ s
kHz
kHz
TA
Ambient operating temperature
T
Ambient storage temperature
S
Insulating material group
m
Mass
Standards 4)
- 40 .. + 85
°C
- 40 .. + 100 °C
III a
10
g
EN 50178 : 1997
IEC 60950-1: 2001
Notes : 1) Absolute value @ TA = 25°C, 2.475 < VOUT < 2.525
2) I = I /N
SPS
3) Only due to TCR
IM
4) Specification according to IEC 1000-4-3 are not guaranteed between
180 and 220 MHz.
Features
• Closed loop (compensated) multi-
range current transducer using the
Hall effect
• Unipolar voltage supply
• Insulated plastic case recognized
according to UL 94-V0
• Compact design for PCB mounting
• Incorporated measuring resistance
• Extended measuring range.
Advantages
• Excellent accuracy
• Very good linearity
• Very low temperature drift
• Optimized response time
• Wide frequency bandwidth
• No insertion losses
• High immunity to external
interference
• Current overload capability.
Applications
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies (UPS)
• Switched Mode Power Supplies (SMPS)
• Power supplies for welding
applications.
Application domain
• Industrial.
Copyright protected.
LEM
TOPE Co., Ltd.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
060227/17
Page 1/3
www.lem.com
Tel: (02) 8228-0658 Fax: (02) 8228-0659 http://www.sensor.tw e-mail: tope@ms1.hinet.net