LF205-S_13 Datasheet, PDF (1/3 Pages) LEM – Current Transducer | |||
|
Current Transducer LF 205-S
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic separation between the primary circuit and the secondary
circuit.
IPN = 200 A
Electrical data
IPN
Primary nominal rms current
IPM
Primary current, measuring range
RM
Measuring resistance @
with ± 12 V
@ ± 200 A max
@ ± 420 A max
with ± 15 V
@ ± 200 A max
@ ± 420 A max
ISN
Secondary nominal rms current
KN
Conversion ratio
UC
Supply voltage (+ 5 %)
IC
Current consumption @ ± 15 V
200
A
0 .. ± 420
A
TA = 70 °C TA = 85 °C
R R R R M min
M max
M min
M max
0 71 0 69 â¦
0 14 0 12 â¦
0 100 23 98 â¦
0 28 23 26 â¦
100
mA
1 : 2000
± 12 .. 15
V
17 + IS
mA
Accuracy - Dynamic performance data
XG
Overall accuracy @ IPN, TA = 25 °C
εL
Linearity error
± 0.5
%
< 0.1
%
Typ Max
IO
Offset current @ IP = 0, TA = 25 °C
± 0.2 mA
IOM
Magnetic offset current 1) @ IP = 0 and specified RM,
after an overload of 3 x IPN
± 0.1 mA
I
OT
Temperature
variation
of
I
O
- 40 °C .. + 85 °C ± 0.12 ± 0.4 mA
tra
Reaction time to 10 % of IPN step
< 500
ns
tr
Response time 2) to 90 % of IPN step
< 1
µs
di/dt di/dt accurately followed
> 100
A/µs
BW Frequency bandwidth (- 3 dB)
DC .. 100
kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
RS
Secondary coil resistance
@ TA = 70 °C
@ TA = 85 °C
m
Mass
Standard
- 40 .. + 85
°C
- 40 .. + 90
°C
33
â¦
35
â¦
78
g
EN 50178: 1997
Features
ââ Closed loop (compensated)
current transducer using the Hall
effect
ââ Insulating plastic case recognized
according to UL 94-V0.
Advantages
ââ Excellent accuracy
ââ Very good linearity
ââ Low temperature drift
ââ Optimized response time
ââ Wide frequency bandwidth
ââ No insertion losses
ââ High immunity to external
interference
ââ Current overload capability.
Applications
ââ AC variable speed drives and
servo motor drives
ââ Static converters for DC motor
drives
ââ Battery supplied applications
ââ Uninterruptible Power Supplies
(UPS)
ââ Switched Mode Power Supplies
(SMPS)
ââ Power supplies for welding
applications.
Application domain
ââ Industrial.
Notes: 1) The result of the coercive force (Hc) of the magnetic circuit
2) With a di/dt of 100 A/µs.
Nº 97.14.44.000.0
8June2013/version 17
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
Page 1/3