English
Language : 

LAH-25-NP Datasheet, PDF (1/3 Pages) LEM – Current Transducer LAH 25-NP
Current Transducer LAH 25-NP
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic separation between the primary circuit and the secondary
circuit.
IP N = 8-12-25 A
Electrical data
IP N Primary nominal RMS current
IP M Primary current, measuring range 1)
RM Measuring resistance @ 2)
with ±12 V
@ IP N [±At DC]
@ IP N [At RMS] 3)
with ±15 V
@ IP N [±At DC]
@ IP N [At RMS] 3)
@
IP
<
I 4)
PN
IS N Secondary nominal RMS current
KN Conversion ratio
UC Supply voltage (±5 %)
IC
Current consumption
25
0 … ±55
TA = 70 °C
R R M min M max
0 284
0 182
67 398
67 263
At
At
TA = 85 °C
R R M min M max
0 280 Ω
0 178 Ω
70 394 Ω
70 259 Ω
25
mA
1-2-3 : 1000
±12 … 15
V
10 (@ ±15 V) +IS
mA
Accuracy - Dynamic performance data
X
Accuracy 5) @ IP N, TA = 25 °C
εL
Linearity error
±0.3
%
< 0.2
%
Typ Max
IO
Offset current @ IP = 0, TA = 25 °C
±0.15
mA
IO M Magnetic offset current @ IP = 0,
and specified RM, after an overload of 5 × IP N
±0.20 ±0.25
mA
IO T Temperature variation of IO 0 °C … +70 °C
±0.10 ±0.60
mA
−25 °C … +85 °C
±0.10 ±0.70
mA
tra
Reaction time to 10 % of IP N
tr
Step response time 6) to 90 % of IP N
BW Frequency bandwidth (−1 dB)
< 200
ns
< 500
ns
DC … 200
kHz
General data
TA Ambient operating temperature
−25 … +85
°C
TS Ambient storage temperature
−40 … +90
°C
RS Resistance of secondary winding @ TA = 70 °C 72
Ω
@ TA = 85 °C 76
Ω
m Mass
20
g
Standards
EN 50178: 1997
Notes: 1) During 10 s, with RM ≤ 109 Ω (UC = ±15 V)
2) Calculation of RM min with the maximum power of the transistors = 0.307 W
@ 70 °C and the maximum power of the transistors = 0.302 W @ 85 °C
3) Sinusoidal wave 50 Hz
4) The minimum measuring resistance RM may be lower
(see “LAH technical information” leaflet)
5) Without IO & IO M
6) With a di/dt of 100 A/µs.
Features
●● Closed loop (compensated) multi-
range current transducer using
the Hall effect
●● Printed circuit board mounting
●● Insulating plastic case recognized
according to UL 94-V0.
Advantages
●● Excellent accuracy
●● Very good linearity
●● Low temperature drift
●● Optimized response time
●● No insertion losses
●● High immunity to external
interference
●● Current overload capability.
Applications
●● AC variable speed drives and
servo motor drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Application domain
●● Industrial.
N° 97.34.19.000.0
24February2017/Version 9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
Page 1/3
www.lem.com