Current Transducer LA 35-NP
For the electronic measurement of currents : DC, AC, pulsed,
mixed, with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
IPN = 7-8-11-17-35 A
Electrical data
16136
I
Primary nominal r.m.s. current
PN
IP
Primary current, measuring range
R
Measuring resistance
M
with ± 15 V
@ ± 35 At max
@ ± 70 At max
ISN
Secondary nominal r.m.s. current
K N Conversion ratio
VC Supply voltage (± 5 %)
IC
Current consumption
Vd
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
Vb
R.m.s. rated voltage 2), safe separation
basic isolation
35 1)
At
0 .. ± 70
At
R
M min
R
M max
60
150 â¦
60
85 â¦
35
mA
1-2-3-4-5 : 1000
± 15
V
10 + IS
mA
2.5
kV
600
V
1700
V
Accuracy - Dynamic performance data
X
εL
IO
I
OM
IOT
tr
di/dt
f
Typical accuracy @ I T = 25°C
PN, A
Linearity
± 0.5
%
< 0.2
%
Typ Max
Offset current 3) @ IP = 0, TA = 25°C
± 0.10 ± 0.20 mA
Residual current 4) @ I = 0, after an overload of 3 x I ± 0.05 ± 0.15 mA
P
PN
Thermal drift of IO
- 25°C .. + 70°C ± 0.15 ± 0.50 mA
Response time 5) @ 90 % of IPN
di/dt accurately followed
<1
> 50
µs
A/µs
Frequency bandwidth (- 1 dB)
DC .. 150
kHz
General data
T
Ambient operating temperature
A
TS
Ambient storage temperature
R
Primary resistance per turn @ T = 25°C
P
A
R S Secondary coil resistance @ TA = 70°C
R
Isolation resistance @ 500 V, T = 25°C
IS
A
m
Mass
Standards
- 25 .. + 70
°C
- 40 .. + 85
°C
< 1.25
mâ¦
80
â¦
> 1500
Mâ¦
22
g
EN 50178 : 1997
Features
⢠Closed loop (compensated) multi-
range current transducer using the
Hall effect
⢠Printed circuit board mounting
⢠Insulated plastic case recognized
according to UL 94-V0.
Advantages
⢠Excellent accuracy
⢠Very good linearity
⢠Low temperature drift
⢠Optimized response time
⢠Wide frequency bandwidth
⢠No insertion losses
⢠High immunity to external
interference
⢠Current overload capability.
Applications
⢠AC variable speed drives and servo
motor drives
⢠Static converters for DC motor drives
⢠Battery supplied applications
⢠Uninterruptible Power Supplies
(UPS)
⢠Switched Mode Power Supplies
(SMPS)
⢠Power supplies for welding
applications.
Notes : 1) In order to avoid over-heating, it is necessary that the recommended
primary connections be followed (see table page 2).
2) Pollution class 2
3) Measurement carried out after 15 mn functioning
4) The result of the coercive field of the magnetic circuit
5) With a di/dt of 100 A/µs.
060719/4
LEM Components
www.lem.com
|
▷ |