English
Language : 

LA25-SP11 Datasheet, PDF (1/2 Pages) LEM – Current Transducer
Current Transducer LA 25-NP/SP11
For the electronic measurement of currents : DC, AC, pulsed,
mixed, with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
IPN = 1 A
Electrical data
16095
IPN
Primary nominal r.m.s. current
IP
Primary current, measuring range
RM Measuring resistance
with ± 15 V
@ ± 1.0 A
max
@ ± 1.5 A max
ISN
Secondary nominal r.m.s. current
K
Conversion ratio
N
VC Supply voltage (± 5 %)
I
Current consumption
C
Vd
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
V
R.m.s. rated voltage 1), safe separation
b
basic isolation
Accuracy - Dynamic performance data
1
A
0 .. ± 1.5
A
RM min
RM max
100 320 Ω
100 190 Ω
25
mA
25 : 1000
± 15
V
10 + I
mA
S
2.5
kV
600
V
1700
V
Features
• Closed loop (compensated) multi-
turns current transducer using the
Hall effect
• Insulated plastic case recognized
according to UL 94-V0.
Special features
• IPN = 1 A
• IP = 0 .. ± 1.5 A
• K N = 25 : 1000.
Advantages
X
ε
Typical accuracy @ IPN , TA = 25°C
Linearity
L
± 0.5
< 0.2
% • Excellent accuracy
% • Very good linearity
Typ Max
• Low temperature drift
IO
IOM
IOT
Offset current 2) @ IP = 0, TA = 25°C
± 0.05 ± 0.15 mA
Residual current 3) @ IP = 0, after an overload of 3 x IPN ± 0.05 ± 0.15 mA
Thermal drift of IO
0°C .. + 25°C ± 0.06 ± 0.25 mA
+ 25°C .. + 70°C ± 0.10 ± 0.35 mA
• Optimized response time
• Wide frequency bandwidth
• No insertion losses
• High immunity to external
interference
tr
Response time 4) @ 90 % of IP max
<1
µs • Current overload capability.
f
Frequency bandwidth (- 1 dB)
DC .. 150 kHz
General data
T
Ambient operating temperature
A
TS
Ambient storage temperature
R
Primary coil resistance @ T = 25°C
P
A
R S Secondary coil resistance @ TA = 70°C
L
Primary insertion inductance
P
R IS Isolation resistance @ 500 V, TA = 25°C
m
Mass
Standards
0 .. + 70
°C
- 25 .. + 85
°C
< 51
mΩ
110
Ω
31
µH
> 1500
MΩ
22
g
EN 50178 : 1997
Notes : 1) Pollution class 2
2) Measurement carried out after 15 mn functioning
3) The result of the coercive field of the magnetic circuit
4) With a di/dt of 100 A/µs.
Applications
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
060405/2
Page 1/2
LEM
www.lem.com