LA25-NP_11 Datasheet, PDF (1/3 Pages) LEM – Current Transducer | |||
|
Current Transducer LA 25-NP
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit and the secondary
circuit.
IPN = 5-6-8-12-25 At
16080
Electrical data
IPN
Primary nominal current rms
IPM
Primary current, measuring range
RM
Measuring resistance @
with ± 15 V
@ ± 25 At max
@ ± 36 At max
ISN
Secondary nominal current rms
KN
Conversion ratio
VC
Supply voltage (± 5 %)
IC
Current consumption
25
At
0 .. ± 36
At
TA = 70°C TA = 85°C
R R R R M min
M max M min
M max
100 320 100 315 â¦
100 190 100 185 â¦
25
mA
1-2-3-4-5 : 1000
± 15
V
10 + IS
mA
Accuracy - Dynamic performance data
X
ε
L
IO
IOM
IOT
tr
di/dt
BW
Accuracy @ IPN, TA = 25°C
Linearity error
± 0.5
< 0.2
Typ Max
Offset current 1) @ IP = 0, TA = 25°C
Magnetic offset current 2) @ IP = 0 and specified RM,
after an overload of 3 x IPN
Temperature variation of IO
0°C .. + 25°C
+ 25°C .. + 70°C
± 0.05 ± 0.15
± 0.05 ± 0.15
± 0.06 ± 0.25
± 0.10 ± 0.35
- 25°C .. + 85°C
± 0.5
- 40°C .. + 85°C
± 1.2
Response time 3) to 90 % of IPN step
di/dt accurately followed
< 1
> 50
Frequency bandwidth (- 1 dB)
DC .. 150
%
%
mA
mA
mA
mA
mA
mA
µs
A/µs
kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
RP
Primary coil resistance per turn @ TA = 25°C
RS
Secondary coil resistance
@ TA = 70°C
@ TA = 85°C
RIS
Isolation resistance @ 500 V, TA = 25°C
m
Mass
Standards
- 40 .. + 85
°C
- 45 .. + 90
°C
< 1.25
mâ¦
110
â¦
115
â¦
> 1500
Mâ¦
22
g
EN 50178: 1997
Features
ââ Closed loop (compensated)
current transducer using the Hall
effect
ââ Isolated plastic case recognized
according to UL 94-V0.
Advantages
ââ Excellent accuracy
ââ Very good linearity
ââ Low temperature drift
ââ Optimized response time
ââ Wide frequency bandwidth
ââ No insertion losses
ââ High immunity to external
interference
ââ Current overload capability.
Applications
ââ AC variable speed drives and
servo motor drives
ââ Static converters for DC motor
drives
ââ Battery supplied applications
ââ Uninterruptible Power Supplies
(UPS)
ââ Switched Mode Power Supplies
(SMPS)
ââ Power supplies for welding
applications.
Application domain
ââ Industrial.
Notes: 1) Measurement carried out after 15 mn functioning
2) The result of the coercive field of the magnetic circuit
3) With a di/dt of 100 A/µs.
9November2011/version 14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
Page 1/3
www.lem.com
|
▷ |