LA150-P_06 Datasheet, PDF (1/2 Pages) LEM – Current Transducer | |||
|
Current Transducer LA 150-P
IPN = 150 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
46090
I
PN DC
IPN
I
PM
RM
I
S
ISN
K
N
VC
I
C
Vd
Primary continuous direct current (nominal)
150
A
Primary nominal current rms
106
A
Primary current, measuring range
0 .. ± 200 A
Measuring resistance
@ ±15V, ± 200 A maxi
Secondary current
TA = 70°C TA = 85 °C
R R RR
M mini M maxi M mini M maxi
0 30
0 15 â¦
75
mA
Secondary nominal current rms
53
mA
Conversion ratio
1 : 2000
Supply voltage (± 5 %)
± 15
V
Current consumption
Rms voltage for AC isolation test, 50 Hz,1min
16 + I
mA
S
2.5
kV
Accuracy-Dynamic performance data
X
εL
I
OE
IOM
IOT
t
r
di/dt
BW
Accuracy @ I , T = 25°C, ± 15 V (± 5 %)
PN DC A
Linearity error (0 .. ± IPN DC)
Electrical offset current @ I = 0, T = 25°C
P
A
Magnetic offset current @ IP = 0 and specified RM ,
after an overload of 1 x I
PN DC
Temperature variation of IO
Response time to 90% of I step
PN DC
di/dt accurately followed
Frequency bandwidth (- 1 dB)1)
< ± 1 % of I
PN DC
± 0.25% of IPN DC
< ± 0.2 mA
< ± 0.15 mA
< ± 0.005 mA
<1
µs
> 200 A/µs
DC .. 150 kHz
General data
TA
Ambient operating temperature
T
Ambient storage temperature
S
RS
Secondary coil resistance
m
Mass
Standards
- 10 .. + 80 °C
- 15 .. + 85 °C
80
â¦
25
g
EN 50178: 1997
Features
⢠Closed loop (compensation) current
transducer using the Hall effect
⢠Printed circuit board mounting
Advantages
⢠Excellent accuracy
⢠Very good linearity
⢠Low temperature drift
⢠Optimized response time
⢠Wide frequency bandwidth
⢠No insertion losses
⢠High immunity to external
interference
⢠Current overload capacity
Applications
⢠AC variable speed drives and servo
motor drives
⢠Static converters for DC motor drives
⢠Battery supplied applications
⢠Uninterruptible Power Supplies
(UPS)
⢠Switched Mode Power Supplies
(SMPS)
⢠Power supplies for welding
applications
Application Domain
⢠Industrial
Notes :
1) Derating is needed to avoid excessive core heating at high frequency.