LA125-P Datasheet, PDF (1/2 Pages) LEM – Current Transducer LA 125-P | |||
|
Current Transducer LA 125-P
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 125 A
Electrical data
IPN
Primary nominal r.m.s. current
I
Primary current, measuring range
P
RM Measuring resistance @
125
A
0 .. ± 200
A
TA = 70°C TA = 85°C
RR RR
M min M max M min M max
with ± 12 V
with ± 15 V
@ ± 125 A
max
@ ± 200 A max
@ ± 125 A
max
@ ± 200 A max
5 52
5 20
25 74
25 34
14 50 â¦
14 18 â¦
40 72 â¦
40 1) 40 1) â¦
ISN
Secondary nominal r.m.s. current
K N Conversion ratio
VC Supply voltage (± 5 %)
IC
Current consumption
Vd
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
125
mA
1 : 1000
± 12 .. 15
V
16 (@ ± 15 V) + IS mA
3
kV
Accuracy - Dynamic performance data
X
Accuracy @ IPN , TA = 25°C
@ ± 15 V (± 5 %) ± 0.60
%
@ ± 12 .. 15 V (± 5 %) ± 0.80
%
εL
Linearity
< 0.15
%
Typ Max
I
Offset current @ I = 0, T = 25°C
O
P
A
± 0.40 mA
IOM Residual current 2) @ IP = 0, after an overload of 3 x IPN
± 0.50 mA
I
Thermal drift of I
OT
O
0°C .. + 70°C ± 0.15 ± 0.50 mA
- 25°C .. + 85°C ± 0.15 ± 0.60 mA
t
ra
tr
di/dt
f
Reaction time @ 10 % of I
P max
Response time 3) 4) @ 90 % of IP max
di/dt accurately followed 4)
Frequency bandwidth 4) (- 1 dB)
< 500
<1
> 200
DC .. 100
ns
µs
A/µ s
kHz
General data
TA
Ambient operating temperature
T
Ambient storage temperature
S
R S Secondary coil resistance @
m
Mass
Standards 5)
- 25 .. + 85
°C
- 40 .. + 90
°C
TA = 70°C 32
â¦
T = 85°C 33.5
A
â¦
40
g
EN 50178
Notes : 1) Measuring range limited to ± 180 A
max
2) The result of the coercive field of the magnetic circuit
3) With a di/dt of 100 A/µs
4) The primary conductor is best filling the through-hole and/or the return
of the primary conductor is above the top of the transducer
5) A list of corresponding tests is available
Features
â¢Closed loop (compensated) current
transducer using the Hall effect
â¢Printed circuit board mounting
â¢Insulated plastic case recognized
according to UL 94-V0.
Advantages
â¢Excellent accuracy
â¢Very good linearity
â¢Low temperature drift
â¢Optimized response time
â¢Wide frequency bandwidth
â¢No insertion losses
â¢High immunity to external
interference
â¢Current overload capability.
Applications
â¢AC variable speed drives and servo
motor drives
â¢Static converters for DC motor drives
â¢Battery supplied applications
â¢Uninterruptible Power Supplies
(UPS)
â¢Switched Mode Power Supplies
(SMPS)
â¢Power supplies for welding
applications.
980716/5
LEM Components
w w w .lem.com
|
▷ |