English
Language : 

LA125-P Datasheet, PDF (1/2 Pages) LEM – Current Transducer LA 125-P
Current Transducer LA 125-P
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 125 A
Electrical data
IPN
Primary nominal r.m.s. current
I
Primary current, measuring range
P
RM Measuring resistance @
125
A
0 .. ± 200
A
TA = 70°C TA = 85°C
RR RR
M min M max M min M max
with ± 12 V
with ± 15 V
@ ± 125 A
max
@ ± 200 A max
@ ± 125 A
max
@ ± 200 A max
5 52
5 20
25 74
25 34
14 50 Ω
14 18 Ω
40 72 Ω
40 1) 40 1) Ω
ISN
Secondary nominal r.m.s. current
K N Conversion ratio
VC Supply voltage (± 5 %)
IC
Current consumption
Vd
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
125
mA
1 : 1000
± 12 .. 15
V
16 (@ ± 15 V) + IS mA
3
kV
Accuracy - Dynamic performance data
X
Accuracy @ IPN , TA = 25°C
@ ± 15 V (± 5 %) ± 0.60
%
@ ± 12 .. 15 V (± 5 %) ± 0.80
%
εL
Linearity
< 0.15
%
Typ Max
I
Offset current @ I = 0, T = 25°C
O
P
A
± 0.40 mA
IOM Residual current 2) @ IP = 0, after an overload of 3 x IPN
± 0.50 mA
I
Thermal drift of I
OT
O
0°C .. + 70°C ± 0.15 ± 0.50 mA
- 25°C .. + 85°C ± 0.15 ± 0.60 mA
t
ra
tr
di/dt
f
Reaction time @ 10 % of I
P max
Response time 3) 4) @ 90 % of IP max
di/dt accurately followed 4)
Frequency bandwidth 4) (- 1 dB)
< 500
<1
> 200
DC .. 100
ns
µs
A/µ s
kHz
General data
TA
Ambient operating temperature
T
Ambient storage temperature
S
R S Secondary coil resistance @
m
Mass
Standards 5)
- 25 .. + 85
°C
- 40 .. + 90
°C
TA = 70°C 32
Ω
T = 85°C 33.5
A
Ω
40
g
EN 50178
Notes : 1) Measuring range limited to ± 180 A
max
2) The result of the coercive field of the magnetic circuit
3) With a di/dt of 100 A/µs
4) The primary conductor is best filling the through-hole and/or the return
of the primary conductor is above the top of the transducer
5) A list of corresponding tests is available
Features
•Closed loop (compensated) current
transducer using the Hall effect
•Printed circuit board mounting
•Insulated plastic case recognized
according to UL 94-V0.
Advantages
•Excellent accuracy
•Very good linearity
•Low temperature drift
•Optimized response time
•Wide frequency bandwidth
•No insertion losses
•High immunity to external
interference
•Current overload capability.
Applications
•AC variable speed drives and servo
motor drives
•Static converters for DC motor drives
•Battery supplied applications
•Uninterruptible Power Supplies
(UPS)
•Switched Mode Power Supplies
(SMPS)
•Power supplies for welding
applications.
980716/5
LEM Components