Current Transducer LA 125-P/SP4
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 125 A
16053
Electrical data
IPN
Primary nominal current rms
125
A
IPM Primary current, measuring range 0 .. ± 300
A
RM Measuring resistance
TA = 70°C TA = 85°C
R R R R M min M max
M min M max
with ± 12 V
@ ± 125 A max
0 89 0 85
Ω
@ ± 200 A max
0 29 0 25
Ω
with ± 15 V
@ ± 125 A max
0 134 0 130 Ω
@ ± 200 A max
0 54 0 50
Ω
@ ± 300 A max
0 11 0 7
Ω
ISN
Secondary nominal current rms
62.5
mA
KN Conversion ratio 1 : 2000
VC Supply voltage (± 5 %) ± 12 .. 15
V
IC
Current consumption 16 (@ ± 15 V) + IS mA
Features
●● Closed loop (compensated)
current transducer using the Hall
effect
●● Printed circuit board mounting
●● Isolated plastic case recognized
according to UL 94-V0.
Special features
●● KN = 1: 2000
●● TA = - 40°C .. + 85°C
●● Potted.
Accuracy - Dynamic performance data
Advantages
X
Accuracy @ IPN , TA = 25°C @ ± 15 V (± 5 %)
± 0.60
@ ± 12 .. 15 V (± 5 %) ± 0.80
ε
L
Linearity error < 0.15
Typ Max
IO
Offset current @ IP = 0, TA = 25°C
± 0.20
IOM
Magnetic offset current 1) @ IP = 0 and specified RM,
after an overload of 3 x IPN
± 0.25
IOT
Temperature variation of IO
- 25°C .. + 85°C ± 0.20 ± 0.50
- 40°C .. - 25°C ± 0.30 ± 0.80
tra
tr
di/dt
Reaction time to 10 % of IPN
Response time 2) 3) to 90 % of IPN step
di/dt accurately followed 4)
< 500
< 1
> 200
BW Frequency bandwidth 4) (- 1 dB) DC .. 100
%
%
%
mA
mA
mA
mA
ns
µs
A/µs
kHz
●● Excellent accuracy
●● Very good linearity
●● Low temperature drift
●● Optimized response time
●● Wide frequency bandwidth
●● No insertion losses
●● High immunity to external
interference
●● Current overload capability.
Applications
●● AC variable speed drives and
servo motor drives
●● Static converters for DC motor
General data
drives
●● Battery supplied applications
TA
Ambient operating temperature - 40.. + 85
°C
TS
Ambient storage temperature - 45 .. + 100
°C
RS Secondary coil resistance
@ TA = 70°C
76
Ω
@ TA = 85°C
80
Ω
m
Mass 55
g
Standards EN 50155: 1995
Notes: 1) Result of the coercive field of the magnetic circuit
2) With a di/dt of 100 A/µs
3) The primary conductor is best filling the through-hole and/or the return of
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Application domain
●● Traction.
the primary conductor is above the top of the transducer.