English
Language : 

LA-150-P Datasheet, PDF (1/4 Pages) LEM – Current Transducer LA 150-P
Current Transducer LA 150-P
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic separation between the primary circuit and the secondary
circuit.
IPN = 150 A
Electrical data
IPN
Primary nominal rms current
IPM
Primary current, measuring range
RM
Measuring resistance @ 85 °C
with ±12 V
@ ±150 A max
@ ±212 A max
with ±15 V
@ ±150 A max
@ ±212 A max
ISN
Secondary nominal rms current
KN
Conversion ratio
UC
Supply voltage (±5 %)
IC
Current consumption
Accuracy - Dynamic performance data
150
A
0 .. ±212
A
R R M min
M max
0
40
Ω
0
3
Ω
0
78
Ω
0
30
Ω
75
mA
1 : 2000
±12 .. 15
V
10 (@ ±15 V) + IS mA
X
Accuracy @ IPN, TA = 25 °C
εL
Linearity error
<0.5
%
<0.1
%
Typ Max
IOE
Electrical offset current @ IP = 0, TA = 25 °C
±0.10 mA
IOM
Magnetic offset current @ IP = 0 and specified RM,
after an overload of 3 × IPN
±0.25 mA
IOT
Temperature variation of IO
-40 °C .. +85 °C ±0.15 ±0.30 mA
tra
Reaction time
<300
ns
tr
Step response time 1) to 90 % of IPN
<500
ns
di/dt di/dt accurately followed
>100
A/µs
BW Frequency bandwidth (-1 dB)
DC .. 150
kHz
General data
TA
Ambient operating temperature
-40 .. +85
°C
TS
Ambient storage temperature
-40 .. +90
°C
RS
Resistance of secondary winding @ TA = 25 °C
64±2
Ω
m
Mass
<25
g
Standards
EN 50178: 1997
UL 508: 2010
Features
●● Closed loop (compensated)
current transducer using the Hall
effect
●● Insulating plastic case recognized
according to UL 94-V0.
Advantages
●● Excellent accuracy
●● Very good linearity
●● Low temperature drift
●● Optimized response time
●● Wide frequency bandwidth
●● No insertion losses
●● High immunity to external
interference
●● Current overload capability.
Applications
●● AC variable speed drives and
servo motor drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Application domain
●● Industrial.
Note: 1) With a di/dt of 100 A/µs.
N° 74.B4.39.000.0
26June2015/version 4
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
Page 1/4
www.lem.com