English
Language : 

HY7-P Datasheet, PDF (1/2 Pages) LEM – Current Transducer
Current Transducer HY7-P
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 7.5 A
Electrical data
Primary nominal
r.m.s. current
IPN (A)
7.5
Primary current
measuring range
IP (A)
± 22.5
Primary
conductor
(mm)
∅1.0
Type
HY 7-P
VC
IC
ÎP
Vd
Vb
R IS
VOUT
ROUT
RL
Supply voltage (± 5 %)
± 15
V
Current consumption
± 10
mA
Overload capability (1 ms)
50 x IPN
R.m.s. voltage for AC isolation test, 50/60Hz, 1 min 2.5
kV
R.m.s. rated voltage, safe separation
5001)
V
Isolation resistance @ 500 VDC
> 1000 MΩ
Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C
±4
V
Output internal resistance
100
Ω
Load resistance
>1
kΩ
Accuracy - Dynamic performance data
X
εL
VOE
VOH
VOT
ε TC G
tr
di/dt
f
Accuracy @ IPN, TA = 25°C (without offset)
Linearity 2) (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
di/dt accurately followed
Frequency bandwidth 3) (- 3 dB)
typ.
max.
<±1
%
< ± 1 % of IPN
< ± 40
mV
< ± 15
mV
± 1.5 mV/K
±3
mV/K
< ± 0.1 %/K
<3
µs
> 50
A/µs
DC .. 50 kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
m
Mass
Standards 4)
- 10 .. + 80 °C
- 25 .. + 85 °C
< 14
g
EN 50178
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2500 V~
• Compact design for PCB mounting
• Low power consumption
• Extended measuring range (3 x IPN)
• Insulated plastic case recognized
according to UL 94-V0.
Advantages
• Easy mounting
• Small size and space savings
• Only one design for wide current
ratings range
• High immunity against external
interference
Applications
• General purpose inverters
• Switched-Mode Power Supplies
(SMPS)
• AC motor speed control
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Power supplies for welding
applications.
Notes : 1) Pollution class 2, overvoltage category III
2) Linearity data exclude the electrical offset.
3) Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency
4) Please consult characterisation report for more technical details and
application advice.
981007/3
LEM Components
www.lem.com
Tope Co., Ltd. Tel: (02) 8228-0658 Fax: (02) 8228-0659 http://www.sensor.com.tw e-mail: tope@ms1.hinet.net