English
Language : 

HY50-P_06 Datasheet, PDF (1/2 Pages) LEM – Current Transducers
Current Transducers HY 50-P
IPN = 50 A
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal
current rms
IPN (A)
50
Primary current,
measuring range
IPM (A)
± 150
Primary
conductor
(mm)
1.6 x 3.5
Type
HY 50-P
RoHS since
date code
45259
VC
Supply voltage (± 5 %)
± 15
V
I
Current consumption
C
± 10
mA
ÎP
Overload capability (1 ms)
50 x IPN
Vd
Rms voltage for AC isolation test, 50 Hz, 1 min
2.5
kV
Vb
Rated isolation voltage rms
500 1)
V
R IS
Isolation resistance @ 500 VDC
> 1000 MΩ
VOUT
Output voltage (Analog) @ ± IPN, RL = 10 kΩ, TA = 25°C ± 4
V
ROUT
Output internal resistance
100
Ω
RL
Load resistance
>1
kΩ
Accuracy - Dynamic performance data
X
εL
VOE
VOH
TCVOE
TCVOUT
t
r
di/dt
BW
Accuracy @ I , T = 25°C (excluding offset)
PN A
Linearity error 2) (0 .. ± IPN)
Electrical offset voltage @ TA = 25°C
Hysteresis offset voltage @ IP = 0,
after an excursion of 1 x IPN
Temperature coefficient of VOE
<±1
<±1
< ± 40
%
% of IPN
mV
< ± 15
typ. ± 1.5
max. ± 3
mV
mV/K
mV/K
Temperature coefficient of VOUT (% of reading)
Response time to 90% of I step
PN
di/dt accurately followed
< ± 0.1
<3
> 50
%/K
µs
A/µs
Frequency bandwidth 3) (- 3 dB)
DC .. 50 kHz
General data
T
Ambient operating temperature
A
TS
Ambient storage temperature
m
Mass
Standards 4)
- 10 .. + 80 °C
- 25 .. + 85 °C
< 14
g
EN 50178: 1997
Notes : 1) Pollution class 2, overvoltage category III.
2) Linearity data exclude the electrical offset.
3) Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency.
4) Please consult characterisation report for more technical details and
application advice.
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2500 V~
• Compact design for PCB mounting
• Low power consumption
• Extended measuring range (3 x IPN)
• Insulated plastic case recognized
according to UL 94-V0.
Advantages
• Easy mounting
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
interference.
Applications
• General purpose inverters
• Switched-Mode Power Supplies
(SMPS)
• AC motor speed control
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Power supplies for welding
applications.
Application domain
• Industrial
061027/5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/2