English
Language : 

HXS20-NP-SP2 Datasheet, PDF (1/3 Pages) LEM – Current Transducer
Current Transducer HXS 20-NP/SP2
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 5 - 10 - 20 A
Electrical data
All Data are given with a RL = 10 kΩ
IPN
I
PM
VOUT
VREF
R
L
ROUT
C
L
VC
I
C
Primary nominal current rms
Primary current, measuring range
Output voltage (Analog) @ IP
I =0
P
Reference voltage 1) - Output voltage
V Output impedance
REF
VREF Load impedance
Load resistance
Output internal resistance
Capacitive loading
Supply voltage (± 5 %)
Current consumption @ V = 5 V
C
± 20
A
± 60
A
VREF ±(0.625·IP/IPN) V
V ± 0.0125 V
REF
2.5 ± 0.025
V
typ. 200
Ω
≥ 200
kΩ
≥2
kΩ
< 10
Ω
<1
µF
5
V
22
mA
Features
• Hall effect measuring principle
• Multirange current transducer
through PCB pattern lay-out
• Galvanic isolation between primary
and secondary circuit
• Isolation test voltage 3500V
• Low power consumption
• Extremely low profile, < 11mm
• Single power supply +5V
• Fixed offset & gain
• Insulated plastic case recognized
according to UL 94-V0.
Accuracy - Dynamic performance data
X
εL
Accuracy 2) @ IPN , TA = 25°C
Linearity error 0 .. IPN
.. 3 x IPN
TCVOE
Temperature coefficient of VOE @ IP = 0
TCVREF Temperature coefficient of VREF
TCVOUT/VREF Temperature coefficient of VOUT / VREF @ IP = 0
TCV
Temperature coefficient of V
OUT
OUT
VOM
Magnetic offset voltage @ IP = 0,
after an overload of 3 x I
PN
tra
Reaction time @ 10 % of IPN
t
Response time to 90 % of I step
r
PN
di/dt
di/dt accurately followed
V
Output voltage noise (DC ..10 kHz)
no
(DC .. 1 MHz)
BW
Frequency bandwidth (-3 dB) 3)
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
m
Mass
Standards
≤±1
≤ ± 0.5
≤±1
≤ ± 0.4
% of IPN
% of IPN
% of IPN
mV/K
≤ ± 0.01
%/K
≤ ± 0.2
mV/K
≤ ± 0.05% of reading/K
< ± 0.7
<3
<5
> 50
< 20
< 40
DC .. 50
% of I
PN
µs
µs
A/µs
mVpp
mVpp
kHz
- 40 .. + 105 °C
- 40 .. + 105 °C
10
g
EN 50178: 1997
Notes : 1) It is possible to overdrive VREF with an external reference voltage
between 2 - 2.8 V providing its ability to sink or source approximately
2.5 mA.
2) Excluding offset and hysteresis.
3) Small signal only to avoid excessive heatings of the magnetic core.
Special Feature
• TA = -40 .. +105 °C
Advantages
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
interference.
• Internal & external reference
Applications
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Application Domain
• Industrial
0 6 1 0 1 8 / 11
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3
www.lem.com