English
Language : 

HX05-NP Datasheet, PDF (1/2 Pages) LEM – Current Transducer HX 05~10-NP
Current Transducer HX 05...10-NP
IPN =
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
5 .. 10 A
Electrical data
Primary nominal
r.m.s. current
IPN (A)
Series
Parallel
±5
± 10
± 10
± 20
Primary current
measuring range
IP (A)
Series
Parallel
± 15
± 30
± 30
± 60
Primary Conductor
Diameter x Turns
(mm)
0.7d x (6T+6T)
1.0d x (3T+3T)
Type
HX 05-NP
HX 10-NP
VOUT
Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C
±4
V
ROUT
Output impedance
< 50
Ω
RL
Load resistance
≥ 10
kΩ
VC
Supply voltage (± 5 %)1)
± 15
V
IC
Current consumption
< ± 20
mA
Vd
R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn
Primary to secondary
>3
kV
Primary 1 to primary 2
>1
kV
Ve
R.m.s. voltage for partial discharge extinction
at 10pC
≥1
kV
Impulse withstand voltage, 1.2/50µs
≥6
kV
Accuracy-Dynamic performance data
X
εL
VOE
VOH
ε VOT
TC G
tr
f
Accuracy @ IPN, TA = 25°C (without offset)
Linearity (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @
after an excursion of 3 x IPN
IP =
0;
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
Frequency bandwidth (-3 dB) 2)
<±1
<±1
< ± 40
< ± 15
max. ± 1.5
± 0.1
≤3
50
% of IPN
% of IPN
mV
mV
mV/K
%/K
µs
kHz
General data
TA
Ambient operating temperature
TS
m
Ambient storage temperature
Mass
- 25 .. + 85 °C
- 25 .. + 85 °C
8
g
Min. internal creepage distance/clearance
≥ 5.5
mm
Isolation material group
I
Standards
EN50178
Notes :1) Also operate at ±12V power supplies, measuring range reduced to ±2.5x IPN
2) Small signal only to avoid excessive heating of the magnetic core
Features
• Galvanic isolation between primary
and secondary circuit
• Hall effect measuring principle
• 2 isolated primary windings
• Isolation voltage 3000V
• Low power consumption
• Extended measuring range(3x IPN)
• Power supply from ±12V to ±15V
• Material according to UL94-V0
Advantages
• Low insection losses
• Easy to mount with automatic
handling system
• Small size and space saving
• High immunity to external
interference.
Applications
• Switched Mode Power Supplies
(SMPS)
• AC variable speed drives
• Uninterruptible Power Supplies
(UPS)
• Electrical appliances
• Battery supplied applications
• DC motor drives
LEM Components
011012/2
www.lem.com