HTS10-P Datasheet, PDF (1/2 Pages) LEM – Current Transducer
HTS 10-P Current Transducer
The HTS 10-P provides electronic measurement of AC,
DC, pulsed, and complex currents with galvanic
isolation between the primary (power) circuit and the
secondary (measurement) circuit.
Electrical Data
Nominal Current
Measurement Range
Sensitivity @ 25°C (note 1)
Overload Capacity
Supply Voltage (note 1)
Primary to Secondary Isolation
Maximum Output (note 2)
10 ARMS
± 15 A
VDD • 20 = 100 mV/A ± 30%
± 25 A for 15 seconds
5.0 VDC ± 10%
2500 VRMS for 1 minute
within 500 mV of each supply rail = 0.5 to 4.5 V
Accuracy-Dynamic Performances
Zero Offset @25°C (note 1)
Linearity @ 25°C
Zero Offset Drift
Magnetic Offset
Gain Drift
Bandwidth, typical
Response Time, typical
VDD / 2 = 2.5 VDC ± 12%
< 0.8% typical, 1.2% maximum
± 2.0 mV/K maximum
± 0.5 % after 45A peak overload
± 0.20 %/K maximum
DC - 16 kHz (-3dB; 10 kHz @ -1dB)
25 µs (with 2 - 10 A/µs rising or falling edge)
General Data
Operating Temperature
Storage Temperature
Current Consumption
Output Current (note 3)
Enclosure and Potting
Weight
Fastening
Output Reference
-40 to 85 °C
-55 to 95 °C
12 mA max @ 5.5VDC
1 mA source and sink
UL Recognized materials meeting UL94-V0
5 grams nominal
PCB Footprint (as shown on page 2)
A positive going output signal is obtained when
the primary current flows from the I+ to I- pin.
Notes:
1) This device is ratiometric: sensitivity and offset vary in direct proportion to supply voltage.
2) Output linearity is not guaranteed within 500mV of the supply rails.
3) Output loading to VDD or VSS must be = 5.1kΩ. Tested with 10kΩ from OUT to VSS.
LEM reserves the right to carry out modifications on its transducers without prior notice.
LEM U.S.A., INC.
Page 1 of 2