Current Transducer HTFS 200..800-P
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 200-400-600-800 A
Electrical data
All Data are given with a RL = 10 kΩ
Primary nominal
Primary current
Type
current rms
measuring range
IPN (A)IPM (A)
200
± 300
HTFS 200-P
400
± 600
HTFS 400-P
600
± 900
HTFS 600-P
800
± 1200
HTFS 800-P
VOUT
VREF
Output voltage (Analog) @ IP
IP = 0
Reference voltage1) - Output voltage
VREF Output impedance
VREF Load impedance
R L Load resistance
ROUT Output internal resistance
C L Capacitive loading
VC
Supply voltage (± 5 %)
IC
Current consumption @ VC = 5 V
VREF ± (1.25ŋIP/ IPN) V
VREF ± 0.025
V
1/2VC ± 0.025
V
typ. 200
Ω
≥ 200
kW
≥2
kΩ
< 10
Ω
<1
µF
5
V
22
mA
Accuracy - Dynamic performance data
X
ε
L
Accuracy 2) @ IPN, TA = 25˃C
Linearity error (0 .. 1.5 x IPN)
TCVOE Temperature coefficient of VOE @ IP = 0
TCVREF Temperature coefficient of VREF
TCVOUT/ VREF Temperature coefficient of VOUT / VREF @ IP = 0
TCVOUT Temperature coefficient of VOUT
VOM Magnetic offset voltage @ IP = 0,
after an overload of 3 x IPN DC
tra
Reaction time @ 10 % of IPN
tr
Response time to 90 % of IPN step
di/dt di/dt accurately followed
Vno Output voltage noise
(DC ..10 kHz)
B W Frequency
bandwidth
(-
3
(DC
dB) 3)
..
1 MHz)
≤±1
≤ ± 0.5
≤ ± 0.3
% of IPN
% of IPN
mV/K
≤ ± 0.01
%/K
≤ ± 0.2
mV/K
≤ ± 0.05 % of reading/K
< ± 0.5
<3
< 7
> 100
< 15
< 40
DC .. 50
% of IPN
µs
µs
A/µs
mVpp
mVpp
kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
m
Mass
Standard
- 40 .. + 105 °C
- 40 .. + 105 °C
60
g
EN 50178: 1997
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Low power consumption
• Single power supply +5V
• Ratiometric offset
• TA = -40..+105 °C
• Fixation by M3 nuts and screws
• Isolated plastic case recognized
according to UL 94-V0.
Advantages
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
interference.
• VREF. IN/OUT.
Applications
• Forklift drives
• AC variable speed drives
• Static converters for DC motor
drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Application domain
Notes : 1) It is possible to overdrive VREF with an external reference voltage
• Industrial.
between 2 - 2.8 V providing its ability to sink or source approx. 2.5 mA.
2) Excluding offset and Magnetic offset voltage.
3) Small signal only to avoid excessive heatings of the magnetic core.
120201/9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3
www.lem.com