English
Language : 

HTFS200-P_05 Datasheet, PDF (1/3 Pages) LEM – Current Transducer
Current Transducer HTFS 200..800-P
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 200 - 400 - 800 A
Electrical data
All Data are given with a RL = 10 kΩ
Primary nominal
r.m.s. current
IPN (A)IP (A)
200
400
800
Primary current
measuring range
± 300
± 600
± 1200
Type
HTFS 200-P
HTFS 400-P
HTFS 800-P
VOUT
VREF
RL
kΩ
ROUT
C
L
VC
IC
Analog output voltage @ IP
VREF±(1.25·IP/IPN) V
IP = 0
VREF ± 0.025
V
Internal Reference1) - Output voltage
1/2VC ± 0.025 V
VREF Output impedance typ. 200
Ω
VREF Load impedance
≥ 200
kΩ
Output load resistance
≥2
Output impedance
Max. output capacitive load
Supply voltage (± 5 %)
Current consumption @ VC = 5 V
< 10
Ω
<1
µF
5
V
22
mA
Accuracy - Dynamic performance data
X
εL
Accuracy 2) @ IPN , TA = 25°C
Linearity error 0 .. 1.5 x IPN
TCVOUT
Thermal drift of VOUT @ IP = 0
TCVREF
Thermal drift of VREF
ε TCVOUT/ VREF Thermal drift of VOUT / VREF @ IP = 0
TC G
Thermal drift of the gain
VOM
Residual voltage @ IP = 0,
after an overload of 3 x IPN DC
tra
Reaction time @ 10 % of IPN
t
Response time @ 90 % of I
r
PN
di/dt
di/dt accurately followed
Output noise (DC ..10 kHz)
(DC .. 1 MHz)
f
Frequency bandwidth (- 3 dB) 3)
≤±1
≤ ± 0.5
≤ ± 0.3
% of IPN
% of IPN
mV/K
≤ ± 0.01
%/K
≤ ± 0.2
mV/K
≤ ± 0.05% of reading/K
< ± 0.5
<3
<7
> 100
< 15
< 40
DC .. 20
% of IPN
µs
µs
A/µs
mVpp
mVpp
kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
UL94 classification
m
Mass
Standards
- 40 .. + 105 °C
- 40 .. + 105 °C
V0
60
g
EN 50178: 1997
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Low power consumption
• Single power supply +5V
• Ratiometric offset
• TA = -40..+105 °C
• Fixation by M3 nuts and screws
Advantages
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
interference.
•
V
REF.
IN/OUT
Applications
• Forklift drives
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Application Domain
• Industrial
Notes : 1) It is possible to overdrive VREF with an external reference voltage
between 2 - 2.8 V providing its ability to sink or source approx. 2.5 mA.
2) Excluding offset.
3) Small signal only to avoid excessive heatings of the magnetic core.
051110/3
LEM
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 1/3
www.lem.com