HTB50-TP Datasheet, PDF (1/2 Pages) LEM – Current Transducers HTB 50~400-P and HTB 50~100-TP | |||
|
Current Transducers HTB 50 .. 400-P
and HTB 50 .. 100-TP
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I = 50 .. 400 A
PN
Electrical data
Primary nominal
r.m.s. current
IPN (A)
50
100
200
300
400
Primary current
measuring range
IP (A)
±150
±300
±500
±600
±600
Type
HTB 50-P, HTB 50-TP1)
HTB 100-P, HTB 100-TP1)
HTB 200-P
HTB 300-P
HTB 400-P
VC
IC
V
d
RIS
VOUT
ROUT
RL
Supply voltage (±5 %) 2)
±12 .. ±15 V
Current consumption
<±15
mA
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn 2.5
kV
Isolation resistance @ 500 VDC
>500
Mâ¦
Output voltage @ ± IPN, RL = 10 kâ¦, TA = 25°C
±4
V
Output internal resistance
100
â¦
Load resistance
â¥10
kâ¦
Accuracy - Dynamic performance data
X
ε
L
V
OE
VOH
VOT
ε TC G
tr
f
Accuracy @ IPN, TA = 25°C (without offset)
Linearity (0 .. ± I )
PN
Electrical offset voltage, T = 25°C
A
Hysteresis offset voltage @ IP = 0;
after an excursion of 3 x I
PN
Thermal drift of VOE HTB 50-(T)P
HTB 100-(T)P..400-P
Thermal drift (% of reading)
Response time @ 90% of IP
Frequency bandwidth (0..-3 dB) 3)
<±1
<±1
<±30
% of IPN
% of I
PN
mV
<±1 % of I
PN
<±2.0 mV/K
<±1.0 mV/K
<±0.1 %/K
<3
µs
DC .. 50 kHz
General data
TA
Ambient operating temperature
T
Ambient storage temperature
S
m
Mass (-TP version)
-20 .. +80 °C
-25 .. +85 °C
<30 (<36) g
2 pins of Ã2mm diameter are available on transducer
for PCB soldering.
Features
⢠Hall effect measuring principle
⢠Galvanic isolation between primary
and secondary circuit
⢠Isolation voltage 2500V
⢠Low power consumption
⢠Wide power supply: ±12V to ±15V
⢠Primary bus bar option for 50A and
100A version for ease of connection
Advantages
⢠Small size and space saving
⢠Only one design for wide current
ratings range
⢠High immunity to external
interference.
Applications
⢠AC variable speed drives
⢠Static converters for DC motor drives
⢠Battery supplied applications
⢠Uninterruptible Power Supplies
(UPS)
⢠Switched Mode Power Supplies
(SMPS)
⢠Power supplies for welding
applications.
Notes : EN 50178 approval pending
1) -TP version is equipped with a primary bus bar.
2) Operating at ±12V ⤠Vc < ±15V will reduce measuring range.
3) Derating is needed to avoid excessive core heating at high frequency.
040720/9
LEM Components