English
Language : 

HTB50-P_07 Datasheet, PDF (1/2 Pages) LEM – Current Transducers
Current Transducers HTB 50..400-P
and HTB 50..100-TP
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN DC = ± 50 .. 400 A
Electrical data
Primary continuous
direct current
(nominal) IPN DC (A)
± 50
± 100
± 200
± 300
± 400
Primary current,
measuring range
IPM (A)
± 150
± 300
± 500
± 600
± 600
Type
RoHS since
date code
HTB 50-P, HTB 50-TP1)
HTB 100-P, HTB 100-TP1)
HTB 200-P
HTB 300-P
HTB 400-P
46104, 46166
45178, 46183
45198
45225
46224
VC
IC
Vd
RIS
VOUT
ROUT
RL
Supply voltage (± 5 %) 2)
± 12 .. 15 V
Current consumption
< ± 15
mA
Rms voltage for AC isolation test, 50 Hz, 1 min
2.5
kV
Isolation resistance @ 500 VDC
> 500
MΩ
Output voltage (Analog) @ ± IPN DC, RL = 10 kΩ, TA = 25°C ± 4
V
Output internal resistance
100
Ω
Load resistance
≥ 10
kΩ
Accuracy - Dynamic performance data
X
εL
V
OE
VOH
TCVOE
TCVOUT
tr
BW
Accuracy @ I , T = 25°C (excluding offset)
PN DC A
< ± 1 % of I
PN DC
Linearity error (0 .. ± IPN DC)
< ± 1 % of IPN DC
Electrical offset voltage, T = 25°C
A
< ± 30
mV
Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN DC
< ± 1 % of IPN DC
Temperature coefficient of VOE HTB 50-(T)P
< ± 2.0 mV/K
HTB 100-(T)P..400-P < ± 1.0 mV/K
Temperature coefficient of VOUT (% of reading)
Response time to 90% of IPN DC
Frequency bandwidth (0..-3 dB) 3)
< ± 0.1 %/K
<3
µs
DC .. 50 kHz
General data
T
Ambient operating temperature
A
TS
Ambient storage temperature
m
Mass (-TP version)
- 20 .. + 80 °C
- 25 .. + 85 °C
< 30 (< 36) g
Standards
EN 50178: 1997
2 pins of Ø2mm diameter are available on transducer
for PCB soldering.
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2500V
• Low power consumption
• Wide power supply: ±12V to ±15V
• Primary bus bar option for 50A and
100A version for ease of connection
Advantages
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
interference.
Applications
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Application domain
• Industrial
Notes :
1) -TP version is equipped with a primary bus bar.
2) Operating at ±12V ≤ Vc < ±15V will reduce measuring range.
3) Derating is needed to avoid excessive core heating at high frequency.
0 7 0 3 1 3 / 11
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/2
www.lem.com