English
Language : 

HTB100-P_07 Datasheet, PDF (1/2 Pages) LEM – Current Transducers
Current Transducers HTB 50..400-P/SP5
and HTB 50..100-TP/SP5
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 50 .. 400 A
Electrical data
Primary nominal
current rms
IPN (A)
50
100
200
300
400
Primary current
measuring range
IPM (A)
± 150
± 300
± 500
± 600
± 600
Type
HTB 50-P/SP5, HTB 50-TP/SP51)
HTB 100-P/SP5, HTB 100-TP/SP51)
HTB 200-P/SP5
HTB 300-P/SP5
HTB 400-P/SP5
VC
IC
V
d
RIS
VOUT
ROUT
RL
Supply voltage (± 5 %) 2)
Current consumption
Rms voltage for AC isolation test, 50 Hz, 1 min
Isolation resistance @ 500 VDC
Output voltage (Analog) @ ± IPN, RL = 10 kΩ, TA = 25°C
Output internal resistance
Load resistance
+ 12 .. 15 V
< 15
mA
2.5
kV
> 500
MΩ
VOE ± 1.667 V
100
Ω
≥ 10
kΩ
Accuracy - Dynamic performance data
X
εL
V
OE
VOH
TCVOE
TCVOUT
tr
BW
Accuracy @ I , T = 25°C (excluding offset)
PN A
< ± 1 % of I
PN
Linearity error (0 .. ± IPN)
< ± 1 % of IPN
Electrical offset voltage @ T = 25°C
A
Vc/2 ± 30 mV
Hysteresis offset voltage @ IP = 0,
after an excursion of 1 x IPN
< ± 0.5 % of IPN
Temperature coefficient of VOE HTB 50-(T)P/SP5
< ± 1.0 mV/K
HTB100-(T)P..400-P/SP5 < ± 0.5 mV/K
Temperature coefficient of VOUT (% of reading)
Response time to 90% of IPN step
Frequency bandwidth (0 .. -3 dB)3)
< ± 0.05 %/K
<3
µs
DC .. 50 kHz
General data
T
Ambient operating temperature
A
TS
Ambient storage temperature
m
Mass (-TP version)
- 25 .. + 85 °C
- 25 .. + 85 °C
< 30 (< 36) g
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2500V
• Low power consumption
• Primary bus bar option for 50A and
100A version for ease of connection
Special feature
• Single power supply from 12V to 15V
Advantages
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
interference.
Applications
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Notes :
1) -TP version is equipped with a primary bus bar.
2) Operating at +12V ≤ Vc < +15V will reduce measuring range.
3) Derating is needed to avoid excessive core heating at high frequency.
0 7 0 111 / 1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/2