HTA100-S_09 Datasheet, PDF (1/3 Pages) LEM – Current Transducer | |||
|
Current Transducer HTA 100 .. 1000-S
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 100 .. 1000 A
Electrical data
Type
Primary nominal Primary current, RoHS since
current rms
measuring range date code
HTA 100-S
IPN (A)
100
IPM (A)
± 300
46179
HTA 200-S
200
± 600
46170
HTA 300-S
300
± 900
46097
HTA 400-S
400
± 1000
46100
HTA 500-S
500
± 1000
46083
HTA 600-S
600
± 1000
46222
HTA 1000-S
1000
± 1000
46118
VOUT Output voltage (Analog) @ ± IPN
RL
Load resistance
TA = 0 .. + 70°C
TA = - 25 .. + 85°C
VC
Supply voltage (± 5 %)
IC
Current consumption
RIS Isolation resistance @ 500 VDC
± 4
V
> 1
kâ¦
> 3
kâ¦
± 15
V
< 25
mA
> 500
Mâ¦
Accuracy - Dynamic performance data
X
ε
L
Accuracy 1) @ IPN , TA = 25°C , @ ± 15 V
Linearity error 1) (0 .. ± IPN)
± 1
%
± 0.5
%
VOE Electrical offset voltage, @ IP = 0, TA = 25°C
< ± 10
mV
VOH Hystersis offset voltage @ IP = 0,
after an excursion of 3 x IPN
< ± 10
mV
TCVOE Temperature coefficient of VOE TA = - 25 .. + 85°C < ± 1
mV/K
TCVOUT Temperature coefficient of VOUT TA = - 25 .. + 85°C < ± 0.05
%/K
tr
Response time to 90 % of IPN step
< 3
µs
di/dt di/dt accurately followed
> 50
A/µs
BW Frequency bandwidth (- 3 dB) 2)
DC .. 50
kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
m
Mass
Standards
Safety
EMC
Deviation in output when tested to EN 61000-4-3
- 25 .. + 85
°C
- 25 .. + 85
°C
230
g
EN 50178(1994)
EN 50082-2(1992)
EN 50081-1(1992)
< 25
% of IPN
Features
ââ Open loop transducer using Hall
effect
ââ Panel mounting-Horizontal or
Vertical
ââ Insulated plastic case recognized
according to UL 94-V0
Advantages
ââ Very good linearity
ââ Very good accuracy
ââ Low temperature drift
ââ Wide frequency bandwidth
ââ Very low insertion losses
ââ High immunity to external
interference
ââ Current overload capability
ââ Low power consumption
ââ Wide dynamic range,
100 to 1000 A in one package.
Applications
ââ AC variable speed drives and
servo motor drives
ââ Static converters for DC motor
drives
ââ Battery supplied applications
ââ Uninterruptible Power Supplies
(UPS)
ââ Switched Mode Power Supplies
(SMPS)
ââ Power supplies for welding
applications.
Application domain
ââ Industrial.
Notes: 1) Excludes the electrical offset
2) Refer to derating curves in the technical file to avoid excessive core
heating at high frequency.
090430/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3