English
Language : 

HAS50-P_12 Datasheet, PDF (1/3 Pages) LEM – Current Transducer
Current Transducer HAS 50 .. 600-P
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit and the secondary
circuit.
IPN = 50 .. 600 A
Electrical data
Type
Primary nominal Primary current, RoHS since
current rms measuring range date code
IPN (A)
HAS 50-P
50
IPM (A)
± 150
46065
HAS 100-P
100
± 300
46062
HAS 200-P
200
± 600
76273
HAS 300-P
300
± 900
76273
HAS 400-P
400
± 900
46131
HAS 500-P
500
± 900
46216
HAS 600-P
600
± 900
76273
VC
Supply voltage (± 5 %) 1)
± 15
V
IC
Current consumption
± 15
mA
RIS Isolation resistance @ 500 VDC
> 1000
MΩ
VOUT Output voltage (Analog) @ ± IPN, RL = 10 kΩ, TA = 25°C ± 4 V ± 40
mV
ROUT Output internal resistance
approx
100
Ω
RL
Load resistance 2)
> 1
kΩ
Accuracy - Dynamic performance data
X
ε
L
Accuracy @ IPN, TA = 25°C (excluding offset)
Linearity error 3) (0 .. ± IPN)
< ± 1
< ± 1
%
% of IPN
VOE Electrical offset voltage, TA = 25°C
< ± 20
mV
VOH Hysteresis offset voltage @ IP = 0,
after an excursion of 1 x IPN < ± 20
mV
TCVOE Temperature coefficient of VOE HAS 50-P
< ± 2
mV/K
HAS 100 .. 600-P < ± 1
mV/K
TCVOUT Temperature coefficient of VOUT (% of reading)
tr
Response time to 90 % of IPN step
di/dt di/dt accurately followed
< ± 0.1
< 3
> 50
%/K
µs
A/µs
BW Frequency bandwidth 4) (small signal, - 3 dB)
DC .. 50
kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
m
Mass
Standard
- 10 .. + 80
°C
- 25 .. + 85
°C
80
g
EN 50178:1997
Features
●● Hall effect measuring principle
●● Galvanic isolation between
primary and secondary circuit
●● Low power consumption
●● Extended measuring range
(3 x IPN)
●● Isolated plastic case made of
polycarbonate PBT recognized
according to UL 94-V0
●● Right angle pins for direct PCB
mounting.
Advantages
●● Easy mounting
●● Small size and space saving
●● Only one design for wide current
ratings range
●● High immunity to external
interference.
Applications
●● AC variable speed drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Notes: 1) Operating at ± 12 V ≤ VC < ± 15 V will reduce the measuring range
2) If the customer uses 1 kΩ of the load resistor, the primary current has to be
limited as the nominal. To measure the full defined measuring range, the
Application domain
●● Industrial.
load resistor should be at minimum 10 kΩ
3) Linearity data exclude the electrical offset
4) Please refer to derating curves in the technical file to avoid excessive core
heating at high frequency.
Page 1/3
29October2012/version 6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com