English
Language : 

HAS50-P Datasheet, PDF (1/2 Pages) LEM – Current Transducers HAS 50~600-P
Current Transducers HAS 50..600-P
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 50..600 A
VOUT = ±4 V
Electrical data
Primary nominal
r.m.s. current
IPN (A)
50
100
200
300
400
500
600
Primary current
measuring range
IP (A)
±150
±300
±600
±900
±900
±900
±900
Type
HAS 50-P
HAS 100-P
HAS 200-P
HAS 300-P
HAS 400-P
HAS 500-P
HAS 600-P
VC
Supply voltage (± 5 %)
±15
V
IC
Current consumption
±15
mA
I
Overload capacity
30,000
At
OC
Vd
R.m.s. voltage for AC isolation test, 60 Hz, 1 mn 3
kV
V
R.m.s. rated voltage, safe separation
5001)
V
b
RIS
Isolation resistance @ 500 VDC
> 1000 MΩ
VOUT
Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C
±4V ±40 mV
ROUT
Output internal resistance
approx. 100
Ω
R
Load resistance
L
>1
kΩ
Accuracy - Dynamic performance data
X
εL
VOE
V
OH
VOT
ε TC G
tr
di/dt
f
Accuracy @ IPN, TA = 25°C (without offset)
Linearity 2) (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IPN→ 0
Thermal drift of VOE HAS 50-P
HAS 100..600-P
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
di/dt accurately followed
Frequency bandwidth (small signal, -1dB) 3) 4)
< ±1
%
< ±1 % of IPN
< ±40
mV
< ±20
mV
< ±2 mV/K
< ±1 mV/K
< ±0.1 %/K
<3
µs
> 50
A/µs
DC .. 25 kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
m
Mass
Standards 5)
- 25 .. + 85 °C
- 25 .. + 85 °C
approx. 80
g
EN 50082-2
Notes : 1) Pollution class 2, overvoltage category III.
2) Linearity data exclude the electrical offset.
3) Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency.
4) Amorphous core option for high frequency application.
5) Please consult characterisation report for more technical details and
application advice.
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 3000 V~
• Low power consumption
• Extended measuring range (3 x IPN)
• Insulated plastic case made of
polycarbonate PBT recognized
according to UL 94-V0
• Right angle pins for direct PCB
mounting
Advantages
• Easy mounting
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
interference.
Applications
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
040406/0
LEM Components
www.lem.com