English
Language : 

EN50178 Datasheet, PDF (1/3 Pages) LEM – Current Transducer LTS 6-NP
Current Transducer LTS 6-NP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 6 At
Electrical data
IPN Primary nominal r.m.s. current
IP
Primary current, measuring range
ÎPDC Overload capability
VOUT Analog output voltage @ IP
IP = 0
N S Number of secondary turns (± 0.1 %)
R L Load resistance
R IM Internal measuring resistance (± 0.5 %)
TCRIM Thermal drift of R IM
VC Supply voltage (± 5 %)
IC
Current consumption @ VC = 5 V
6
At Features
0 .. ± 19.2
At
250
At • Closed loop (compensated) multi-
2.5 ± (0.625·IP/IPN) V
2.5 1)
V
range current transducer using the
Hall effect
2000
• Unipolar voltage supply
≥2
k Ω • Compact design for PCB mounting
208.33
Ω • Insulated plastic case recognized
< 50
ppm/K
according to UL 94-V0
5
V • Incorporated measuring resistance
Typ 28+IS2) +(VOUT/RL)mA • Extended measuring range.
Accuracy - Dynamic performance data
Advantages
X
Accuracy @ IPN , TA = 25°C
εL
Accuracy with R IM @ IPN , TA = 25°C
Linearity error
TCVOUT Thermal drift of VOUT @ IP = 0
- 10°C .. + 85°C
- 40°C .. - 10°C
ε TC G Thermal drift of the gain
- 40°C .. + 85°C
VOM Residual voltage @ IP = 0,after an overload of 3 x IPN
5 x IPN
10 x IPN
tr a
Reaction time @ 10 % of IPN
tr
Response time @ 90 % of IPN
di/dt di/dt accurately followed
f
Frequency bandwidth (0 .. - 0.5 dB)
(- 0.5 .. 1 dB)
± 0.2
%
± 0.7
%
< 0.1
%
Typ Max
80 200 ppm/K
250 ppm/K
50 3) ppm/K
± 0.5
mV
± 2.0
mV
± 2.0
mV
< 100
< 400
> 15
DC .. 100
DC .. 200
ns
ns
A/µs
kHz
kHz
General data
TA
Ambient operating temperature
TS Ambient storage temperature
Insulating material group
m Mass
Standards 4)
- 40 .. + 85
°C
- 40 .. + 100 °C
III a
10
g
EN 50178 : 1997
IEC 60950-1 : 2001
• Excellent accuracy
• Very good linearity
• Very low temperature drift
• Optimized response time
• Wide frequency bandwidth
• No insertion losses
• High immunity to external
interference
• Current overload capability.
Applications
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies (UPS)
• Switched Mode Power Supplies (SMPS)
• Power supplies for welding
applications.
Application domain
• Industrial.
Notes : 1) Absolute value @ TA = 25°C, 2.475 < VOUT < 2.525
2) Please see the operation principle on the other side
Copyright protected.
3) Only due to TCRIM
4) Specification according to IEC 61000-4-3 are not guaranteed between
95 and 110 MHz (value higher by 5% than the specification).
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
050713/14
Page 1/3
LEM Components
www.lem.com
Tope Co., Ltd. Tel: (02) 8228-0658 Fax: (02) 8228-0659 http://www.sensor.com.tw e-mail: tope@ms1.hinet.net