English
Language : 

CTSR0.6-TP-SP2 Datasheet, PDF (1/10 Pages) LEM – Current Transducer
Current Transducer CTSR 0.6-TP/SP2
IPRN = 600 mA
For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between
the primary circuit and the secondary circuit.
Features
Applications
●● Closed loop (compensated) current transducer
●● Voltage output
●● Single supply voltage
●● PCB mounting
●● Four integrated primary conductors.
Special feature
●● No retention pin.
Advantages
●● Residual current measurement
●● Leakage current measurement in transformerless PV
inverters
●● First human contact protection of PV arrays
●● Failure detection in power sources
●● Symmetrical fault detection (e.g. after motor inverter)
●● Leakage current detection in stacked DC sources
●● Single phase or three phase nominal current measurement
up to ± 30 A per wire (DC or AC).
●● High accuracy
Standards
●● Very low offset drift over temperature
●● High overload capability
●● High insulation capability
●● Reference pin with two modes, Ref In and Ref Out
●● Degauss and test functions
●● EN 50178: 1997
●● IEC 61010-1: 2010
●● UL 508: 2010.
Application Domain
●● Possibility to add up to four primary wires (diam. 4.2 mm
●● Industrial
max) in addition to the already integrated primary conductors. ●● Suitable to fulfil VDE 0126-1-1, UL 1741.
N°97.H3.G6.002.0
28January2014/version 6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
Page 1/10
www.lem.com