CT100-S_06 Datasheet, PDF (1/2 Pages) LEM – Current Transducer | |||
|
Current Transducer CT 100-S
For very accurate measurements of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Provisional
IPN = 100 A
Electrical data
IP N
I
P
VO U T
K
N
RL
C
L
tC
V
C
IC
V
d
Primary nominal r.m.s. current
Primary current, measuring range
Analog output voltage
Conversion ratio
Load resistance
Capacitance loading
Output short-circuit duration 1)
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
100
A
0 .. ± 150
A
5
V
100 A / 5 V
> 500
â¦
â¤5
nF
â
s
± 15
V
90 + VOUT / R L m A
6
kV
Accuracy - Dynamic performance data
X
Overall accuracy @ I
G
PN
- 25°C .. + 70°C
VO
t
r
di/dt
f
Offset voltage @ IP = 0
TA = 25°C
- 25°C .. + 70°C
Response time 2) @ 90 % de I
PN
di/dt accurately followed
Frequency bandwidth (- 3 dB) @ 10 % of IPN
± 0.15
%
Typ Max
± 0.4 mV
± 0.6 mV
400
60
DC .. 250
ns
A/µs
kHz
General data
T
Ambient operating temperature
A
TS
Ambient storage temperature
m
Mass
Standards
- 25 .. + 70
°C
- 40 .. + 85
°C
670
g
EN 50178 : 1997
Notes : 1) If the short-circuit has a duration more than 1 s, the primary current of
the supply voltage must be interrupted for a short time to restore the
transducer to proper working order. The internal protection is done by
PTC resistors
2) With a di/dt of 60 A/µs.
Features
⢠Closed loop (compensated) current
transducer
⢠Insulated plastic case recognized
according to UL 94-V0
⢠Patent pending.
Advanced features
⢠f = 250 kHz
â¢
X
G
=
± 0.15 % (- 25°C .. + 70°C).
Advantages
⢠Excellent accuracy
⢠Very good linearity
⢠Low temperature drift
⢠Optimized response time
⢠Wide frequency bandwidth
⢠No insertion losses
⢠High immunity to external
interference
⢠Current overload capability.
Applications
⢠AC variable speed drives and servo
motor drives
⢠Static converters for DC motor drives
⢠Battery supplied applications
⢠Uninterruptible Power Supplies
(UPS)
⢠Switched Mode Power Supplies
(SMPS)
⢠Power supplies for welding
applications.
060808/5
LEM
www.lem.com
|
▷ |