AV100-2000 Datasheet, PDF (1/2 Pages) LEM – Voltage Transducer | |||
|
Voltage Transducer AV 100-2000
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
VPN = 2000 V
Electrical data
VPN
VPmax
VË P
RP
RM
ISN
VC
IC
Vd
Ve
Primary nominal r.m.s. voltage
Primary voltage measuring range
Non-measurable overload
Primary input resistance
Measuring resistance
@ VC=11.4V
@ VC=22.8V
Secondary nominal r.m.s. current
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 min
Max Common mode voltage
and
R.m.s. voltage for partial discharge
extinction @ 10pC
Accuracy - Dynamic performance data
2000
V
± 30001)
V
4500 (1s/h) VDC
17.8M
â¦
RM min
0
RM max
47
â¦
0
184 â¦
50
mA
DC± 12 .. 24 V
50+IS
mA
6.5
kV
U HT+ + UHT- ⤠4.2 k V DC
UHT+ - UHT-⤠VPMAX
2.2
kV
Features
⢠Insulated plastic case recognized
according to UL 94-V0
⢠Included primary resistor.
Advantages
⢠Low power
⢠Excellent accuracy
⢠Very good linearity
⢠Low thermal drift
⢠Low response time
⢠High bandwidth
⢠High immunity to external
interference
⢠Low disturbance in common mode.
X G Overall Accuracy @ VPN , TA = + 25°C
X G Overall Accuracy @ VPN , TA = - 25 .. + 70°C
εX G
L
Overall Accuracy @ VPN , TA = - 40 .. + 85°C
Linearity @ TA = 25°C
IO
Offset current @ VP = 0, TA = 25°C
tr
Response time @ 10 % of VPN
f
Frequency bandwidth (- 3 dB)
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
m Mass
Standards
± 0.7
%
± 1.5
%
± 1.7
%
< 0.1
%
± 0.15
mA
< 12
µs
DC .. 13
kHz
- 40 .. + 85
°C
- 50 .. + 90
°C
375
g
EN 50155 (01.12.02)
EN 50124-1 (01.03.01)
NFF16101/2 (01.10.88)
Applications
⢠AC variable speed drives and servo
motor drives
⢠Static converters for DC motor drives
⢠Battery supplied applications
⢠Uninterruptible Power Supplies
(UPS)
⢠Power supplies for welding
applications .
Note : 1) Up to 2200 Vpk, 500 ms every 60 minutes & 2600 Vpk, 500 ms,12
times/year.
030805/2
LEM Components
|
▷ |