AK-C420L Datasheet, PDF (1/2 Pages) LEM – AC Current transducer | |||
|
AC Current transducer AK-C420L
Transducer for the electronic measurement AC sinusoidal waveforms
current, with galvanic isolation between the primary (High power) and
the secondary circuits (Electronic circuit). Jumper selectable ranges
and 4-20mA current output.
IPN = 2 .. 200 A
Electrical data
Primary Nominal Current
I (A.t.RMS)
PN
2, 5
10, 20, 50
100, 150, 200
Analogue Output Signal1) Type
I (mA)
OUT
RoHS
Date Code
4-20
4-20
4-20
AK 5 C420L
AK 50 C420L
AK 200 C420L
MAY 2006
MAY 2006
planned
Vc Supply voltage (Loop powered)
24
R Load resistance
L
see power supply diagram
Vb Rated voltage (CAT III, PD2)
150
Vd RMS Isolation voltage test, 50 Hz, 1mn
3
f
Frequency bandwith
20-100
V DC
V AC
kV AC
Hz
Accuracy - Dynamic performance data
X
Accuracy @ IPN, TA=25°C
tr
Response time @ 90% of IPN
±1
%
< 300
ms
General data
T Ambient operating temperature (0-95% RH)
-20..+50
°C
A
T Ambient storage temperature
S
-20..+85
°C
m Mass
120
g
Safety
IEC 61010-1
EMC
EN 61326
Note: 1) For 4-20mA output model, no saturation output up to 25 mA.
Features
⢠AC sinusoïdal Measurement
⢠Average responding
⢠Current output
⢠Loop powered transducers
⢠Panel mounting
⢠Accurate
⢠Jumper selectable ranges
Advantages
⢠Large aperture
⢠High isolation between primary and
secondary circuits
⢠Easy to mount
Applications
⢠Automation systems
Analog current reading for remote
monitoring (e.g. motor).
⢠Data loggers
Self-powered transducer does not
drain data logger batteries.
⢠Panel meters
Simple connection displays power
consumption.
Options on request
⢠DIN mounting
LEM
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
060512/6
Page 1/2
www.lem.com
|
▷ |