AC Current transducer AK-C-
Transducer for the electronic measurement of AC sinusoidal waveforms,
with galvanic isolation between the primary (High power) and the
secondary circuits (Electronic circuit). Jumper selectable ranges and
self powered transducers.
IPN = 10 .. 200 A
Electrical data
Primary Nominal Current Analogue Output Signal1)
IPN (A.t.RMS)
10,20,50
10,20,50
100,150,200
100,150,200
VOUT (V DC)
5
10
5
10
Type
RoHS
Date code
AK 50 C5
AK 50 C10
AK 200 C5
AK 200 C10
planned
MAY 2006
planned
JUNE 2006
Vc Supply voltage
RL Load resistance
Vb Rated voltage (CAT III, PD2)
Vd RMS Isolation voltage test, 50 Hz, 1mn
f
Frequency bandwith
Self Powered
1
150
3
50-60
MΩ
V AC
kV AC
Hz
Accuracy - Dynamic performance data
Features
• AC sinusoïdal measurement
• Average responding
• Self powered transducers
• Panel mounting
• Voltage output
• Jumper selectable ranges
Advantages
• Large aperture
• High isolation between primary and
secondary circuits
• Easy to mount
X
Accuracy @ IPN, TA=25°C
t
Response time @ 90% of I
r
PN
±1
< 100
General data
T
Ambient operating temperature (0-95% RH)
A
T
Ambient storage temperature
S
m Mass
Safety
EMC
- 20 ..+ 50
- 20 ..+ 85
120
IEC 61010-1
EN 61326
Note : 1) For 0-5 V output model, no saturation output up to 8.2 V
and for 0-10 V output model, no saturation output up to 15 V.
% Applications
mS
• Automation systems
Analog current reading for remote
monitoring (e.g. motor).
• Data loggers
°C
Self-powered transducer does not
drain data logger batteries.
°C
• Panel meters
g
Simple connection displays power
consumption.
Options on request
• DIN mounting
LEM
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
060816/6
Page 1/2
www .lem.com