English
Language : 

AHR-B10 Datasheet, PDF (1/3 Pages) LEM – AC/DC Current transducer
AC/DC Current transducer AHR-B10
The transducer for the electronic measurement of DC & distorted AC
waveform currents, with galvanic isolation between the primary circuit
(power) and the secondary circuit (measurement).
True RMS 0-10 V voltage output.
IPN = 500 .. 2000 A
Electrical data
Primary nominal
DC & AC current
IPN (At rms)
500
800
1000
1500
2000
Primary AC current
max. peak value 1)
IP (A)
2000
2500
2000
2500
3000
Output voltage
(Analog)
VOUT (VDC)
0-10
0-10
0-10
0-10
0-10
RL
Load resistance
V
Supply voltage
C
IC
Current Consumption
V
Output voltage limitation
SL
ÎP
Overload capability (Ampere Turns)
Performance data
X
εL
V
OE
TCVOE
TCVOUT
t
r
BW
Accuracy @ I , T = 25°C (excluding offset)
PN A
Linearity error (1% of IPN .. ± IPN)
Electrical offset voltage, T = 25°C
A
Temperature coefficient of VOE ( 0 .. + 60 °C)
(- 40 .. + 70 °C)
Temperature coefficient of VOUT (% of reading)
Response time to 90% of I step
PN
Frequency bandwidth (±1 dB)
General data
T
A
TS
m
IPxx
Ambient operating temperature
Ambient storage temperature
Mass
Protection degree
Type
AHR 500 B10
AHR 800 B10
AHR 1000 B10
AHR 1500 B10
AHR 2000 B10
≥ 10
kΩ
+ 20 .. 50 V DC
35
mA
< 14
V
30000
At
< ±1 % of I
PN
< ±1.0 % of IPN
< ±1.0 % of I
PN
± 2.0 mV/K
± 4.0 mV/K
± 0.15 %/K
< 150
ms
DC, 20 .. 6000Hz
- 40 .. + 70 °C
- 40 .. + 85 °C
650
g
IP20
Features
• DC + distorted AC waveform currents
measurement
• True RMS output
• Busbar or panel mounting
• Split core type
• Insulated plastic case recognized
according to UL94-V0.
Advantages
• High isolation between primary and
secondary circuits
• Eliminates insertion loss
• Easy installation.
Applications
• AC power supplies or Motors:
True RMS current sensing - the most
accurate way to monitor power supply
or motor input power
• VFD Controlled Loads:
VFD output current monitoring to
indicate how the motor and the
attached load are operating
• SCRs or Switch-mode Rectifiers:
Accurate measurement of output
current
Note :
1) The max. peak AC current is the highest peak level of the primary signal that is
taken into account for accurate true r.m.s. calculation. Yet the device is designed
for maximum continuous true r.m.s value equal to IPN, whereas the output is limited
by the above specified output limitation.
• Renewable Energy Installations or
Backup Batteries:
Continuous condition minitoring
allowing automatic failure detection/
anticipation.
Application domain
061128/6
• Energy and Automation
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3
www.lem.com